Radiofrequency antenna concepts for human cardiac MR at 14.0 T.
Nurzed, Bilguun; Kuehne, Andre; Aigner, Christoph Stefan; Schmitter, Sebastian; Niendorf, Thoralf; Eigentler, Thomas Wilhelm.
  • Nurzed B; Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Robert Rössle Strasse 10, 13125, Berlin, Germany.
  • Kuehne A; MRI.TOOLS GmbH, Berlin, Germany.
  • Aigner CS; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Berlin, Germany.
  • Schmitter S; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Berlin, Germany.
  • Niendorf T; Max-Delbrück-Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin Ultrahigh Field Facility (B.U.F.F.), Robert Rössle Strasse 10, 13125, Berlin, Germany. thoralf.niendorf@mdc-berlin.de.
  • Eigentler TW; MRI.TOOLS GmbH, Berlin, Germany. thoralf.niendorf@mdc-berlin.de.
MAGMA ; 36(2): 257-277, 2023 Apr.
Article en En | MEDLINE | ID: mdl-36920549
OBJECTIVE: To examine the feasibility of human cardiac MR (CMR) at 14.0 T using high-density radiofrequency (RF) dipole transceiver arrays in conjunction with static and dynamic parallel transmission (pTx). MATERIALS AND METHODS: RF arrays comprised of self-grounded bow-tie (SGBT) antennas, bow-tie (BT) antennas, or fractionated dipole (FD) antennas were used in this simulation study. Static and dynamic pTx were applied to enhance transmission field (B1+) uniformity and efficiency in the heart of the human voxel model. B1+ distribution and maximum specific absorption rate averaged over 10 g tissue (SAR10g) were examined at 7.0 T and 14.0 T. RESULTS: At 14.0 T static pTx revealed a minimum B1+ROI efficiency of 0.91 µT/√kW (SGBT), 0.73 µT/√kW (BT), and 0.56 µT/√kW (FD) and maximum SAR10g of 4.24 W/kg, 1.45 W/kg, and 2.04 W/kg. Dynamic pTx with 8 kT points indicate a balance between B1+ROI homogeneity (coefficient of variation < 14%) and efficiency (minimum B1+ROI > 1.11 µT/√kW) at 14.0 T with a maximum SAR10g < 5.25 W/kg. DISCUSSION: MRI of the human heart at 14.0 T is feasible from an electrodynamic and theoretical standpoint, provided that multi-channel high-density antennas are arranged accordingly. These findings provide a technical foundation for further explorations into CMR at 14.0 T.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Corazón Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Corazón Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article