Your browser doesn't support javascript.
loading
Clinical Validation of a Wearable Piezoelectric Blood-Pressure Sensor for Continuous Health Monitoring.
Min, Seongwook; Kim, Dong Hyun; Joe, Daniel J; Kim, Byung Woo; Jung, Young Hoon; Lee, Jae Hee; Lee, Bo-Yeon; Doh, Il; An, Jaehun; Youn, Young-Nam; Joung, Boyoung; Yoo, Chang D; Ahn, Hyo-Suk; Lee, Keon Jae.
  • Min S; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Kim DH; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Joe DJ; Safety Measurement Institute, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.
  • Kim BW; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Jung YH; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Lee JH; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Lee BY; Department of Nature-Inspired System and Application, Korea Institute of Machinery and Materials (KIMM), 156 Gajeongbuk-ro, Yuseong-gu, Daejeon, 34103, Republic of Korea.
  • Doh I; Safety Measurement Institute, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.
  • An J; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Youn YN; Division of Cardiovascular Surgery, Severance Cardiovascular Hospital, Yonsei University, College of Medicine, Yonsei University Health System, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Joung B; Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
  • Yoo CD; Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Ahn HS; Department of Internal Medicine, Division of Cardiology, Uijeongbu St Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, Republic of Korea.
  • Lee KJ; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Adv Mater ; 35(26): e2301627, 2023 Jun.
Article en En | MEDLINE | ID: mdl-36960816
ABSTRACT
Wearable blood-pressure sensors have recently attracted attention as healthcare devices for continuous non-invasive arterial pressure (CNAP) monitoring. However, the accuracy of wearable blood-pressure (BP) monitoring devices has been controversial due to the low signal quality of sensors, the absence of an accurate transfer function to convert the sensor signals into BP values, and the lack of clinical validation regarding measurement precision. Here, a wearable piezoelectric blood-pressure sensor (WPBPS) is reported, which achieves a high normalized sensitivity (0.062 kPa-1 ), and fast response time (23 ms) for CNAP monitoring. The transfer function of a linear regression model is designed, offering a simple solution to convert the flexible piezoelectric sensor signals into BP values. In order to verify the measurement accuracy of WPBPS, clinical trials are performed on 35 subjects aged from 20 to 80 s after screening. The mean difference between the WPBPS and a commercial sphygmomanometer of 175 BP data pairs is -0.89 ± 6.19 and -0.32 ± 5.28 mmHg for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. By building a WPBPS-embedded wristwatch, the potentially promising use of a convenient, portable, continuous BP monitoring system for cardiovascular disease diagnosis is demonstrated.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presión Arterial / Dispositivos Electrónicos Vestibles Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presión Arterial / Dispositivos Electrónicos Vestibles Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article