Your browser doesn't support javascript.
loading
Quantitative Evaluation of Non-basic Nitrogen-Containing Compounds in Petroleum-Derived Samples by Direct Injection ESI (-) Orbitrap MS.
de Aguiar, Deborah V A; Lima, Gesiane da S; Roque, Jussara V; Oliveira, João V A; Medeiros Júnior, Iris; Gomes, Alexandre de O; N Mendes, Luiz A; Vaz, Boniek G.
  • de Aguiar DVA; Institute of Chemistry, Federal University of Goiás, Goiânia, Goiás 74690-900, Brazil.
  • Lima GDS; Institute of Chemistry, Federal University of Goiás, Goiânia, Goiás 74690-900, Brazil.
  • Roque JV; Institute of Chemistry, Federal University of Goiás, Goiânia, Goiás 74690-900, Brazil.
  • Oliveira JVA; Institute of Chemistry, Federal University of Goiás, Goiânia, Goiás 74690-900, Brazil.
  • Medeiros Júnior I; CENPES, PETROBRAS, Rio de Janeiro, Rio, 21941-915, Brazil.
  • Gomes AO; CENPES, PETROBRAS, Rio de Janeiro, Rio, 21941-915, Brazil.
  • N Mendes LA; CENPES, PETROBRAS, Rio de Janeiro, Rio, 21941-915, Brazil.
  • Vaz BG; Institute of Chemistry, Federal University of Goiás, Goiânia, Goiás 74690-900, Brazil.
Anal Chem ; 95(16): 6507-6513, 2023 Apr 25.
Article en En | MEDLINE | ID: mdl-37058365
The quantification of non-basic nitrogen-containing compounds (NCCs) in petroleum-derived samples has become a critical issue due to the undesirable effects of these compounds on the petroleum industry. In addition, there is a lack of analytical methods that allow the direct quantification of NCCs in these matrices. This paper provides strategies for obtaining quantitative information of NCCs in petroleum-derived samples using direct flow injection electrospray ionization (ESI) (-) Orbitrap mass spectrometry without fractionation steps. Benzocarbazole (BC) quantification was performed using the standard addition method. The method was validated, and all analytical parameters demonstrated satisfactory results in the matrix-mix. Paired Student's t-test exhibited the matrix effect (95% confidence level, p < 0.05). Limits of detection ranged from 2.94 to 14.91 µg L-1, and the limits of quantification ranged from 9.81 to 49.69 µg L-1. Intraday and interday accuracy and precision were not above 15%. Quantification of non-basic NCCs was carried out based on two approaches. In approach 1, the non-basic NCCs' total content in petroleum-derived samples was determined by the BC concentration and the total abundance correction. The method presented good performance with the average error of 21, 8.3, and 28% for crude oil, gas oil, and diesel samples, respectively. Approach 2 was based on the multiple linear regression model with regression significant at a 0.05 significance level within average relative errors of 16, 7.8, and 17% for the crude oil, gas oil, and diesel samples, respectively. Then, both approaches successfully predicted the quantification of non-basic NCCs by ESI direct flow injection.

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Prognostic_studies Idioma: En Año: 2023 Tipo del documento: Article