Your browser doesn't support javascript.
loading
Demonstration of improved laser preheat with a cryogenically cooled magnetized liner inertial fusion platform.
Harvey-Thompson, A J; Geissel, M; Crabtree, J A; Weis, M R; Gomez, M R; Fein, J R; Lewis, W E; Ampleford, D J; Awe, T J; Chandler, G A; Galloway, B R; Hansen, S B; Hanson, J; Harding, E C; Jennings, C A; Kimmel, M; Knapp, P F; Mangan, M A; Maurer, A; Paguio, R R; Perea, L; Peterson, K J; Porter, J L; Rambo, P K; Robertson, G K; Rochau, G A; Ruiz, D E; Shores, J E; Slutz, S A; Smith, G E; Smith, I C; Speas, C S; Yager-Elorriaga, D A; York, A.
  • Harvey-Thompson AJ; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Geissel M; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Crabtree JA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Weis MR; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Gomez MR; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Fein JR; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Lewis WE; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Ampleford DJ; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Awe TJ; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Chandler GA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Galloway BR; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Hansen SB; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Hanson J; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Harding EC; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Jennings CA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Kimmel M; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Knapp PF; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Mangan MA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Maurer A; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Paguio RR; General Atomics, San Diego, California 92121, USA.
  • Perea L; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Peterson KJ; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Porter JL; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Rambo PK; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Robertson GK; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Rochau GA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Ruiz DE; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Shores JE; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Slutz SA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Smith GE; General Atomics, San Diego, California 92121, USA.
  • Smith IC; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Speas CS; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • Yager-Elorriaga DA; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
  • York A; Sandia National Laboratories, P.O. Box 5800, Albuquerque, New Mexico 87185, USA.
Rev Sci Instrum ; 94(5)2023 May 01.
Article en En | MEDLINE | ID: mdl-37184347
ABSTRACT
We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2023 Tipo del documento: Article