Your browser doesn't support javascript.
loading
Quantifying Hand Strength and Isometric Pinch Individuation Using a Flexible Pressure Sensor Grid.
Conway, Brian J; Taquet, Léon; Boerger, Timothy F; Young, Sarah C; Krucoff, Kate B; Schmit, Brian D; Krucoff, Max O.
  • Conway BJ; Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Taquet L; Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Boerger TF; Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Young SC; Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Krucoff KB; Department of Plastic & Reconstructive Surgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Schmit BD; Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Krucoff MO; Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
Sensors (Basel) ; 23(13)2023 Jun 26.
Article en En | MEDLINE | ID: mdl-37447773
ABSTRACT
Modulating force between the thumb and another digit, or isometric pinch individuation, is critical for daily tasks and can be impaired due to central or peripheral nervous system injury. Because surgical and rehabilitative efforts often focus on regaining this dexterous ability, we need to be able to consistently quantify pinch individuation across time and facilities. Currently, a standardized metric for such an assessment does not exist. Therefore, we tested whether we could use a commercially available flexible pressure sensor grid (Tekscan F-Socket [Tekscan Inc., Norwood, MA, USA]) to repeatedly measure isometric pinch individuation and maximum voluntary contraction (MVC) in twenty right-handed healthy volunteers at two visits. We developed a novel equation informed by the prior literature to calculate isometric individuation scores that quantified percentage of force on the grid generated by the indicated digit. MVC intra-class correlation coefficients (ICCs) for the left and right hands were 0.86 (p < 0.0001) and 0.88 (p < 0.0001), respectively, suggesting MVC measurements were consistent over time. However, individuation score ICCs, were poorer (left index ICC 0.41, p = 0.28; right index ICC -0.02, p = 0.51), indicating that this protocol did not provide a sufficiently repeatable individuation assessment. These data support the need to develop novel platforms specifically for repeatable and objective isometric hand dexterity assessments.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dedos / Individualismo Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dedos / Individualismo Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article