Your browser doesn't support javascript.
loading
Impact of the Drug Loading Method on the Drug Distribution and Biological Efficacy of Exosomes.
Kumar, Dulla Naveen; Chaudhuri, Aiswarya; Kumar, Dinesh; Singh, Sanjay; Agrawal, Ashish Kumar.
  • Kumar DN; Department of Pharmaceutical Engineering & Technology, Indian Institute of Technology, Banaras Hindu University, Varanasi, 221005, Uttar Pradesh, India.
  • Chaudhuri A; Department of Pharmaceutical Engineering & Technology, Indian Institute of Technology, Banaras Hindu University, Varanasi, 221005, Uttar Pradesh, India.
  • Kumar D; Department of Pharmaceutical Engineering & Technology, Indian Institute of Technology, Banaras Hindu University, Varanasi, 221005, Uttar Pradesh, India.
  • Singh S; Department of Pharmaceutical Engineering & Technology, Indian Institute of Technology, Banaras Hindu University, Varanasi, 221005, Uttar Pradesh, India.
  • Agrawal AK; Department of Pharmaceutical Engineering & Technology, Indian Institute of Technology, Banaras Hindu University, Varanasi, 221005, Uttar Pradesh, India. ashish.phe@itbhu.ac.in.
AAPS PharmSciTech ; 24(6): 166, 2023 Aug 08.
Article en En | MEDLINE | ID: mdl-37552397
Exosomes are biological nanovesicles that are intrinsically loaded with thousands of biomacromolecules and are principally responsible for cell-to-cell communication. Inspired by the natural payload, they have been extensively investigated as drug delivery vehicles; however, the drug distribution, whether into or onto exosomes, is still debatable. In the present work, we have tried to investigate it systemically by selecting 5-fluorouracil (5-FU) (hydrophilic) and paclitaxel (PAC) (hydrophobic), drugs with very different physicochemical characteristics, for the loading to the exosomes. Exosomes were obtained from bovine milk, and the drugs were loaded using three different methods: incubation, sonication, and triton x-100. The particle size was found to be approximately 100 nm in all the cases; however, the highest drug loading was found in the sonication method. Fluorescence spectrophotometer, EDX analysis, EDX mapping, XPS, and XRD analysis indicated the possible presence of more drugs over the surface in the case of the incubation method. Drugs loaded by the sonication method had more controlled release than simple incubation and triton x-100. The method of drug loading had an insignificant effect on the cytotoxicity while in line with our previous observation, the combination (PAC and 5-FU) exhibited synergism as evidenced by ROS assay, colony formation assay, and mitochondrial membrane potential assay.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Exosomas Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Exosomas Idioma: En Año: 2023 Tipo del documento: Article