Your browser doesn't support javascript.
loading
Clinical outcomes of TAVI with the Myval balloon-expandable valve for non-calcified aortic regurgitation.
Sanchez-Luna, Juan Pablo; Martín, Pedro; Dager, Antonio E; Charry, Pablo D; Beltrán, Javier R; Sánchez-Recalde, Ángel; Giannini, Francesco; Gómez-Menchero, Antonio; Pan, Manuel; Ielasi, Alfonso; Monastyrski, Andrea; Barbanti, Marco; Fernandez-Avilés, Francisco; Ancona, Marco Bruno; Mussayev, Abdurashid; De Brahi, Juan Pablo; Lamelas, Pablo; Sánchez-Pérez, Andrés; García Puerta, Melissa; Ortiz, Miguel; Gonzalez-Gutiérrez, Jose Carlos; Marengo, Giorgio; Gómez, Javier; Gonzalez-Bartol, Esther; Stepanenko, Alexander; Gomez-Salvador, Itziar; San Román, J Alberto; Amat-Santos, Ignacio J.
  • Sanchez-Luna JP; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Martín P; Cardiology Department, Hospital Universitario de Gran Canaria Dr Negrin, Las Palmas, Gran Canaria, Spain.
  • Dager AE; Cardiology Department, Angiografía de Occidente Hospital, Cali, Colombia.
  • Charry PD; Cardiology Department, Clínica Medilaser, Neiva, Colombia.
  • Beltrán JR; Cardiology Department, Los Comuneros Hospital Universitario de Bucaramanga, Bucaramanga, Colombia.
  • Sánchez-Recalde Á; Cardiology Department, Hospital Universitario Ramón y Cajal, Madrid, Spain.
  • Giannini F; Cardiology Department, San Raffaele Scientific Institute, Milan, Italy.
  • Gómez-Menchero A; Cardiology Department, Hospital Juan Ramón Jimenez, Huelva, Spain.
  • Pan M; Cardiology Department, Hospital Reina Sofía, Cordoba, Spain and University of Cordoba (IMIBIC), Cordoba, Spain.
  • Ielasi A; Cardiology Department, IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy.
  • Monastyrski A; Cardiology Department, Hospital Universitario Val d'Hebron, Barcelona, Spain.
  • Barbanti M; Cardiology Department, Policlinico-Vittorio Emanuele Hospital, Catania, Italy.
  • Fernandez-Avilés F; Cardiology Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
  • Ancona MB; Cardiology Department, San Raffaele Scientific Institute, Milan, Italy.
  • Mussayev A; Cardiology Department, National Research Cardiac Surgery Center, Astana, Kazakhstan.
  • De Brahi JP; Cardiology Department, Sanatorio de La Trinidad Mitre, Buenos Aires, Argentina.
  • Lamelas P; Cardiology Department, Instituto Cardiovascular, Buenos Aires, Argentina.
  • Sánchez-Pérez A; Cardiology Department, Hospital Universitario de Gran Canaria Dr Negrin, Las Palmas, Gran Canaria, Spain.
  • García Puerta M; Cardiology Department, Angiografía de Occidente Hospital, Cali, Colombia.
  • Ortiz M; Cardiology Department, Angiografía de Occidente Hospital, Cali, Colombia.
  • Gonzalez-Gutiérrez JC; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Marengo G; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Gómez J; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Gonzalez-Bartol E; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Stepanenko A; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Gomez-Salvador I; Centro de Investigación Biomédica en Red, Enfermedades Cardiovasculares, Madrid, Spain.
  • San Román JA; Cardiology Department, Hospital Clinico Universitario de Valladolid, Valladolid, Spain.
  • Amat-Santos IJ; Centro de Investigación Biomédica en Red, Enfermedades Cardiovasculares, Madrid, Spain.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Article en En | MEDLINE | ID: mdl-37565470
ABSTRACT

BACKGROUND:

Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting.

AIMS:

We aimed to evaluate the safety and feasibility of Myval in NCAR.

METHODS:

This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed.

RESULTS:

A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047).

CONCLUSIONS:

Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Estenosis de la Válvula Aórtica / Prótesis Valvulares Cardíacas / Reemplazo de la Válvula Aórtica Transcatéter Tipo de estudio: Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Año: 2023 Tipo del documento: Article