Your browser doesn't support javascript.
loading
Comparison of two hydroxyapatite-coated femoral components: a randomized clinical trial using radiostereometric analysis.
Turgeon, Thomas R; Righolt, Christiaan H; Burnell, Colin D; Gascoyne, Trevor C; Hedden, David R; Bohm, Eric R.
  • Turgeon TR; Concordia Joint Replacement Group, Winnipeg, Canada.
  • Righolt CH; Department of Surgery, University of Manitoba, Winnipeg, Canada.
  • Burnell CD; Concordia Joint Replacement Group, Winnipeg, Canada.
  • Gascoyne TC; Orthopaedic Innovation Centre, Winnipeg, Canada.
  • Hedden DR; Concordia Joint Replacement Group, Winnipeg, Canada.
  • Bohm ER; Department of Surgery, University of Manitoba, Winnipeg, Canada.
Bone Joint J ; 105-B(10): 1045-1051, 2023 Oct 01.
Article en En | MEDLINE | ID: mdl-37782569
Aims: The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components. Methods: Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020. Radiostereometric analysis examinations at six, 12, and 24 months were used to assess the migration of each implanted femoral component compared to a baseline assessment. Patient-reported outcome measures were also recorded for these same timepoints. Overall, 50 patients were enrolled (62% male (n = 31), with a mean age of 65.7 years (SD 7.3), and mean BMI of 30.2 kg/m2 (SD 5.2)). Results: The two-year subsidence was similar for Avenir (-0.018 mm (95% confidence interval (CI) -0.053 to 0.018) and Corail (0.000 mm (95% CI -0.027 to 0.026; p = 0.428). Both anteversion/retroversion (Avenir 0.139° (95% CI -0.204 to 0.481°); Corail -0.196° (95% CI -0.445 to 0.053°; p = 0.110) and varus/valgus tilt (Avenir -0.024° (95% CI -0.077 to 0.028); Corail -0.049° (95% CI -0.098 to 0.000°; p = 0.473) were not statistically significantly different. After two years, patients reported similar improvements in EuroQol five-dimension five-level health questionnaire (Avenir 0.22 (SD 0.2); Corail 0.22 (SD 0.18); p = 0.965) and other outcomes scores. Patient satisfaction on a five-point Likert scale was also similar between both groups after two years (Avenir 1.38 (SD 0.88); Corail 1.33 (SD 0.57); p = 0.846). Conclusion: The performance of both femoral components was similar in terms of stability and patient outcomes.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male Idioma: En Año: 2023 Tipo del documento: Article