Your browser doesn't support javascript.
loading
Cortical bone adaptation response is region specific, but not peak load dependent: insights from µ CT image analysis and mechanostat simulations of the mouse tibia loading model.
Miller, Corey J; Pickering, Edmund; Martelli, Saulo; Dall'Ara, Enrico; Delisser, Peter; Pivonka, Peter.
  • Miller CJ; School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, Australia. corey.miller@hdr.qut.edu.au.
  • Pickering E; School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, Australia.
  • Martelli S; School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, Australia.
  • Dall'Ara E; Department of Oncology and Metabolism and Insigneo Institute for In Silico Medicine, University of Sheffield, Sheffield, UK.
  • Delisser P; Veterinary Specialist Services, Brisbane, Australia.
  • Pivonka P; School of Mechanical, Medical and Process Engineering, Queensland University of Technology (QUT), Brisbane, Australia. peter.pivonka@qut.edu.au.
Biomech Model Mechanobiol ; 23(1): 287-304, 2024 Feb.
Article en En | MEDLINE | ID: mdl-37851203
The two major aims of the present study were: (i) quantify localised cortical bone adaptation at the surface level using contralateral endpoint imaging data and image analysis techniques, and (ii) investigate whether cortical bone adaptation responses are universal or region specific and dependent on the respective peak load. For this purpose, we re-analyse previously published µ CT data of the mouse tibia loading model that investigated bone adaptation in response to sciatic neurectomy and various peak load magnitudes (F = 0, 2, 4, 6, 8, 10, 12 N). A beam theory-based approach was developed to simulate cortical bone adaptation in different sections of the tibia, using longitudinal strains as the adaptive stimuli. We developed four mechanostat models: universal, surface-based, strain directional-based, and combined surface and strain direction-based. Rates of bone adaptation in these mechanostat models were computed using an optimisation procedure (131,606 total simulations), performed on a single load case (F = 10 N). Subsequently, the models were validated against the remaining six peak loads. Our findings indicate that local bone adaptation responses are quasi-linear and bone region specific. The mechanostat model which accounted for differences in endosteal and periosteal regions and strain directions (i.e. tensile versus compressive) produced the lowest root mean squared error between simulated and experimental data for all loads, with a combined prediction accuracy of 76.6, 55.0 and 80.7% for periosteal, endosteal, and cortical thickness measurements (in the midshaft of the tibia). The largest root mean squared errors were observed in the transitional loads, i.e. F = 2 to 6 N, where inter-animal variability was highest. Finally, while endpoint imaging studies provide great insights into organ level bone adaptation responses, the between animal and loaded versus control limb variability make simulations of local surface-based adaptation responses challenging.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tibia / Adaptación Fisiológica Límite: Animals Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tibia / Adaptación Fisiológica Límite: Animals Idioma: En Año: 2024 Tipo del documento: Article