Your browser doesn't support javascript.
loading
NiCo2O4/Ti2NbC2 (double MXene) nanohybrid-based non-enzymatic electrochemical biosensor for the detection of glucose in sweat.
Subramania, Ashok Kumar; Sugumaran, Sivanandam; Sethuramalingam, Prakash; Ramesh, Rajasekaran; Dhandapani, Preethi; Angaiah, Subramania.
  • Subramania AK; Department of Biomedical Engineering, Saveetha Engineering College, Chennai, 602105, India.
  • Sugumaran S; Department of Biomedical Engineering, Saveetha Engineering College, Chennai, 602105, India. sivanandams@saveetha.ac.in.
  • Sethuramalingam P; Department of Biomedical Engineering, Saveetha Engineering College, Chennai, 602105, India.
  • Ramesh R; Department of Biomedical Engineering, Saveetha Engineering College, Chennai, 602105, India.
  • Dhandapani P; Centre for Nanoscience and Technology, Pondicherry University, Puducherry, 605014, India.
  • Angaiah S; Centre for Nanoscience and Technology, Pondicherry University, Puducherry, 605014, India. a.subramania@gmail.com.
Bioprocess Biosyst Eng ; 46(12): 1755-1763, 2023 Dec.
Article en En | MEDLINE | ID: mdl-37855914
ABSTRACT
The non-enzymatic electrochemical sensors are attractive due to their high sensitivity, quick detection, low cost, and simple construction. Hence, in this work, a non-enzymatic biosensor was constructed with NiCo2O4 nanoparticles (~ 82 nm) decorated over Ti2NbC2 nanosheets by an in-situ method. The crystal structure, phase purity, morphology and elemental composition of the synthesized NiCo2O4/Ti2NbC2 nanohybrid was investigated using XRD, Raman and FESEM analysis. The electrocatalytic and electrochemical behaviour of the prepared nanohybrid was investigated using cyclic voltammetry and amperometry analysis. Hybrid of NiCo2O4/Ti2NbC2 produces a biocompatible, electrochemically active surface with enhanced electrical conductivity. The enhanced surface area of NiCo2O4 and superior electrical conductivity of Ti2NbC2 nanosheets helped to develop non-enzymatic electrochemical glucose sensor with enhanced sensitivity (425.6 µA mM-1cm-2), low limit of detection and quick response time that satisfy glucose detection applications. Thus, the developed non-enzymatic electrochemical glucose sensor has excellent electrochemical properties and making it as a strong candidate for the detection of glucose concentration in sweat.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Glucosa Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Glucosa Idioma: En Año: 2023 Tipo del documento: Article