Your browser doesn't support javascript.
loading
A Smartphone-Integrated Molecularly Imprinted Fluorescence Sensor for Visual Detection of Chlortetracycline Based on N,P-Codoped Carbon Dots Decorated Iron-Based Metal-Organic Frameworks.
Zhang, Jinni; Liu, Yan; Cui, Xueyan; Cao, Yichuan; Li, Yan; Fang, Guozhen; Wang, Shuo.
  • Zhang J; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Liu Y; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Cui X; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Cao Y; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Li Y; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Fang G; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
  • Wang S; State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China.
J Agric Food Chem ; 71(43): 16303-16309, 2023 Nov 01.
Article en En | MEDLINE | ID: mdl-37856445
ABSTRACT
The residue of chlortetracycline is potentially hazardous to human health; it is meaningful to exploit a portable, rapid, sensitive, and selective method for detection of chlortetracycline (CTC). In this study, a novel fluorescence bionic sensing probe (NH2-MIL-53&N,P-CDs@MIP) was successfully prepared based on the nitrogen and phosphorus codoped carbon dots decorated iron-based metal-organic frameworks combining with molecular imprinted polymer for the detection of CTC. A fluorescence intensity-responsive "on-off" detection of CTC on account of the inner-filter effect (IFE) was achieved by NH2-MIL-53&N,P-CDs@MIP. Under the optimal conditions, the fluorescence quenching degree of NH2-MIL-53&N,P-CDs@MIP presented a good linear relationship with the CTC concentration in the range 0.06-30 µg mL-1 and the limit of detection (LOD) was 0.019 µg mL-1. The fluorescent probe was applied to detect CTC in milk samples, and experimental results showed a good recovery rate (88.73%-96.28%). Additionally, a smartphone-integrated fluorescence sensing device based on NH2-MIL-53&N,P-CDs@MIP was exploited to replace the expensive and bulky fluorescence spectrophotometer for quantitative determination of CTC with the LOD of 0.033 µg mL-1. The sensing system showed high selectivity, strong stability, high specificity, and portability, which provide a great strategy for the quantitative detection of antibiotic residue.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Clortetraciclina / Puntos Cuánticos / Impresión Molecular / Estructuras Metalorgánicas Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Clortetraciclina / Puntos Cuánticos / Impresión Molecular / Estructuras Metalorgánicas Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article