Micro simulated moving bed chromatography-mass spectrometry as a continuous on-line process analytical tool.
Diehm, Juliane; Witting, Lennart; Kirschhöfer, Frank; Brenner-Weiß, Gerald; Franzreb, Matthias.
  • Diehm J; Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
  • Witting L; Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
  • Kirschhöfer F; Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
  • Brenner-Weiß G; Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany.
  • Franzreb M; Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344, Eggenstein-Leopoldshafen, Germany. matthias.franzreb@kit.edu.
Anal Bioanal Chem ; 416(2): 373-386, 2024 Jan.
Article en En | MEDLINE | ID: mdl-37946036
ABSTRACT
Continuous manufacturing is becoming increasingly important in the (bio-)pharmaceutical industry, as more product can be produced in less time and at lower costs. In this context, there is a need for powerful continuous analytical tools. Many established off-line analytical methods, such as mass spectrometry (MS), are hardly considered for process analytical technology (PAT) applications in biopharmaceutical processes, as they are limited to at-line analysis due to the required sample preparation and the associated complexity, although they would provide a suitable technique for the assessment of a wide range of quality attributes. In this study, we investigated the applicability of a recently developed micro simulated moving bed chromatography system (µSMB) for continuous on-line sample preparation for MS. As a test case, we demonstrate the continuous on-line MS measurement of a protein solution (myoglobin) containing Tris buffer, which interferes with ESI-MS measurements, by continuously exchanging this buffer with a volatile ammonium acetate buffer suitable for MS measurements. The integration of the µSMB significantly increases MS sensitivity by removing over 98% of the buffer substances. Thus, this study demonstrates the feasibility of on-line µSMB-MS, providing a versatile PAT tool by combining the detection power of MS for various product attributes with all the advantages of continuous on-line analytics.