Your browser doesn't support javascript.
loading
Distribution of PCDD/Fs and PCBs at different locations in a circulating fluidised bed municipal solid waste incinerator.
Zhang, Mengmei; Fujimori, Takashi; Lin, Xiaoqing; Li, Xiaodong.
  • Zhang M; Nanxun Innovation Institute, Zhejiang University of Water Resources and Electric Power, Hangzhou, 310018, China. zhangmm@zju.edu.cn.
  • Fujimori T; Ecology and Environmental Engineering Course, Faculty of Advanced Science and Technology, Ryukoku University, Shiga, 5202194, Japan.
  • Lin X; State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering, Zhejiang University, Hangzhou, 310027, China.
  • Li X; State Key Laboratory of Clean Energy Utilization, Institute for Thermal Power Engineering, Zhejiang University, Hangzhou, 310027, China.
Environ Sci Pollut Res Int ; 31(6): 8552-8565, 2024 Feb.
Article en En | MEDLINE | ID: mdl-38180672
ABSTRACT
This study investigates a circulating fluidised bed (CFB) incineration plant to examine the concentrations and fingerprints of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and biphenyls (PCBs) at five locations downstream of the post-combustion zone. Sampling encompassed both flue gas and ash, spanning from the high-temperature superheater to the outlet of the baghouse filter, thus covering a wide range of flue gas temperatures. The analysis reveals a continuous increase in PCDD/F and PCB concentrations in the flue gas from the superheater to the inlet of the air pollution control system (APCS). The maximum concentrations observed were 75.8 ng/Nm3 for PCDDs, 219 ng/Nm3 for PCDFs, and 763 ng/Nm3 for PCBs. These values represent 9.14, 11.5, and 6.37 times their respective concentrations at the outlet of the high-temperature superheater. Concurrently, the levels of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in the ash steadily increased along the cooling path of the flue gas within the plant. Comparing dl-PCBs to the total amount of 209 PCB congeners, it was evident that dl-PCBs exhibited a trend more akin to that of PCDD/Fs. A robust linear correlation was observed between dl-PCBs and PCDD/Fs (R2 = 0.99, p < 0.001), surpassing that between PCBs and PCDD/Fs (R2 = 0.92, p < 0.01), suggesting that dl-PCBs share closer formation pathways with PCDD/Fs. Additionally, elemental composition analysis of fly ash samples aimed to explore potential links between fly ash characteristics and PCDD/F and PCB formation. The Cl/S ratio increased from 1.58 to 5.13 with decreasing flue gas temperature. Principal component analysis (PCA) was employed to visualise the concentrations of PCDD/Fs and PCBs in the flue gas alongside elemental contents in the fly ash. With the exception of PCBs in ash, all other PCDD/Fs and PCBs in fly ash exhibited positive correlations with both carbon (C) and chlorine (Cl). Furthermore, a positive relationship between C/Cl and PCDD/Fs-PCBs in fly ash implies that fly ash serves as the primary reaction surface for dioxin generation during low-temperature heterogeneous catalytic reactions.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bifenilos Policlorados / Dioxinas / Dibenzodioxinas Policloradas Idioma: En Año: 2024 Tipo del documento: Article