Your browser doesn't support javascript.
loading
Correction of Rectus Abdominis Diastasis: A Prospective Comparative Study Between a New Suturable Polypropylene Mesh vs Polypropylene Standard Suture Plication.
Aesthet Surg J ; 44(6): 633-640, 2024 May 15.
Article en En | MEDLINE | ID: mdl-38243919
ABSTRACT

BACKGROUND:

Duramesh (Mesh Suture Inc., Chicago, IL) is a new suturing concept, combining the principles of mesh with the precision, flexibility, and versatility of a suture, suitable also for abdominal rectus diastasis (ARD) correction.

OBJECTIVES:

This prospective research aimed to compare mesh with the standard polypropylene suture plication for rectus diastasis repair with regard to safety (infection, seroma, hematoma, surgical wound dehiscence, and fistula rates and hospital stay); effectiveness (ARD recurrence by ultrasound sonography, palpability of the muscular suture, surgical time, and postoperative pain evaluation); and satisfaction of the patients based on the BODY-Q, a patient-reported outcome measure.

METHODS:

Sixty-five of the initial 70 patients who underwent rectus diastasis repair with a 6-month follow-up were randomly divided into 2 groups, comprising 33 patients treated with Duramesh and 32 patients treated with standard 0 polypropylene suture plication. Data regarding infection, seroma, hematoma, surgical wound dehiscence, and fistula rates; hospital stay; ARD recurrence; palpability of the muscular suture; surgical time; postoperative pain evaluation (measured by visual analog scale, or VAS); and the BODY-Q were analyzed by Prism 9 (GraphPad Software Inc., San Diego, CA).

RESULTS:

No significant differences were reported between the 2 groups with regard to infection, seroma, hematoma, surgical wound dehiscence, and fistula rates and hospital stay. The mesh decreased the time required to perform plication compared with standard polypropylene detached sutures. No statistically significant differences were found with respect to the VAS and BODY-Q data.

CONCLUSIONS:

Duramesh 0 application for rectus diastasis repair is safe and effective without compromising aesthetic improvement when compared with standard 0 polypropylene plication.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polipropilenos / Mallas Quirúrgicas / Técnicas de Sutura / Recto del Abdomen / Diástasis Muscular Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polipropilenos / Mallas Quirúrgicas / Técnicas de Sutura / Recto del Abdomen / Diástasis Muscular Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article