Your browser doesn't support javascript.
loading
Electrochemiluminescent resonance energy transfer between amino-modified g-C3N4/Bi2MoO6 composite and carboxyl CoS2 nanoboxes for sensitive detection of alpha fetoprotein.
Ali, Asghar; Khan, Sonia; Li, Zheng.
  • Ali A; Institute for Advanced Study, Shenzhen University, Shenzhen 518060, PR China.
  • Khan S; Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Li Z; Institute for Advanced Study, Shenzhen University, Shenzhen 518060, PR China. Electronic address: zhengli24@szu.edu.cn.
Talanta ; 271: 125709, 2024 May 01.
Article en En | MEDLINE | ID: mdl-38290268
ABSTRACT
This work demonstrates an effective quenching electrochemiluminescent (ECL) immunosensor based on resonance energy transfer for the sensitive detection of alpha fetoprotein (AFP). In this strategy, graphitic carbon nitride (g-C3N4) was coupled with bismuth molybdenum oxide (Bi2MoO6) to form a g-C3N4/Bi2MoO6 nanocomposite as a novel type of ECL immunosensor. The as-synthesized amino-modified g-C3N4/Bi2MoO6 nanocomposite presents strong and stable cathodic ECL activity compared to pristine g-C3N4. One plausible reason is that the synergistic effect between the g-C3N4 and Bi2MoO6 could facilitate charge transfer process and thereby enhancing the separation efficiency of electron-hole pairs. The other functional part of the immunosensor, carboxyl CoS2 nanoboxes with a broad absorption range, was rationally designed and introduced. The evidence that the absorption spectra of carboxyl CoS2 NBs overlap with ECL spectra of g-C3N4/Bi2MoO6 nanocomposite holds accountable for exceptionally weakened ECL signal. This sandwich-type immunosensor was setup based on quenching mechanism concerning amino-modified g-C3N4/Bi2MoO6 as an ECL donor and carboxyl CoS2 NBs as an ECL accepter. The strategy was optimized to achieve a convincible and sensitive detection goal for AFP with a wide quantifiable range of 0.5 pg/mL-10 ng/mL whilst a sufficiently low detection limit of 0.04 pg/mL (S/N = 3). This immunosensor shows great potential for real sample analysis with reasonable recoveries ranging from 95.5 to 99.0 %, demonstrating its high precision for AFP determination.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bismuto / Técnicas Biosensibles / Alfa-Fetoproteínas / Molibdeno Tipo de estudio: Diagnostic_studies Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bismuto / Técnicas Biosensibles / Alfa-Fetoproteínas / Molibdeno Tipo de estudio: Diagnostic_studies Idioma: En Año: 2024 Tipo del documento: Article