Your browser doesn't support javascript.
loading
A Self-Localization Algorithm for Mobile Targets in Indoor Wireless Sensor Networks Using Wake-Up Media Access Control Protocol.
Souissi, Rihab; Sahnoun, Salwa; Baazaoui, Mohamed Khalil; Fromm, Robert; Fakhfakh, Ahmed; Derbel, Faouzi.
  • Souissi R; Smart Diagnostic and Online Monitoring, Leipzig University of Applied Sciences, Wächterstraße 13, 04107 Leipzig, Germany.
  • Sahnoun S; Laboratory of Signals, Systems, Artificial Intelligence and Networks (SM@RTS), Digital Research Center of Sfax (CRNS), Sfax University, Sfax 3021, Tunisia.
  • Baazaoui MK; National School of Electronics and Telecommunications of Sfax, Sfax 3018, Tunisia.
  • Fromm R; Laboratory of Signals, Systems, Artificial Intelligence and Networks (SM@RTS), Digital Research Center of Sfax (CRNS), Sfax University, Sfax 3021, Tunisia.
  • Fakhfakh A; National School of Electronics and Telecommunications of Sfax, Sfax 3018, Tunisia.
  • Derbel F; Smart Diagnostic and Online Monitoring, Leipzig University of Applied Sciences, Wächterstraße 13, 04107 Leipzig, Germany.
Sensors (Basel) ; 24(3)2024 Jan 25.
Article en En | MEDLINE | ID: mdl-38339519
ABSTRACT
Indoor localization of a mobile target represents a prominent application within wireless sensor network (WSN), showcasing significant values and scientific interest. Interference, obstacles, and energy consumption are critical challenges for indoor applications and battery replacements. A proposed tracking system deals with several factors such as latency, energy consumption, and accuracy presenting an innovative solution for the mobile localization application. In this paper, a novel algorithm introduces a self-localization algorithm for mobile targets using the wake-up media access control (MAC) protocol. The developed tracking application is based on the trilateration technique with received signal strength indication (RSSI) measurements. Simulations are implemented in the objective modular network testbed in C++ (OMNeT++) discrete event simulator using the C++ programming language, and the RSSI values introduced are based on real indoor measurements. In addition, a determination approach for finding the optimal parameters of RSSI is assigned to implement for the simulation parameters. Simulation results show a significant reduction in power consumption and exceptional accuracy, with an average error of 1.91 m in 90% of cases. This method allows the optimization of overall energy consumption, which consumes only 2.69% during the localization of 100 different positions.