Improving the Sensitivity and Linear Range of Photoionization Ion Mobility Spectrometry via Confining the Ion Recombination and Space Charge Effects Assisted by Theoretical Modeling.
Xu, Yiqian; Yang, Qimu; Pan, Manman; Jiang, Dandan; Yu, Yi; Chen, Chuang; Li, Haiyang.
  • Xu Y; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China.
  • Yang Q; University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
  • Pan M; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China.
  • Jiang D; Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China.
  • Yu Y; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China.
  • Chen C; University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
  • Li H; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China.
Anal Chem ; 96(9): 3979-3987, 2024 Mar 05.
Article en En | MEDLINE | ID: mdl-38391328
ABSTRACT
Photoionization (PI) is an efficient ionization source for ion mobility spectrometry (IMS) and mass spectrometry. Its hyphenation with IMS (PI-IMS) has been employed in various on-site analysis scenarios targeting a wide range of compounds. However, the signal intensity and linear dynamic range of PI-IMS at ambient pressure usually do not follow the Beer-Lambert law predictions, and the factors causing that negative deviation remain unclear. In this work, a variable pressure PI-IMS system was developed to examine the ion loss effects from factors like ion recombination and space charge by varying its working pressure from 1 to 0.1 bar. Assisted by theoretical modeling, it was found that ion recombination could contribute up to 90% of signal intensity loss for ambient pressure PI-IMS setups. Lowering the pressure and increasing the electric field in PI-IMS helped suppress the ion recombination process and thus an optimal pressure Poptimal appeared for best signal intensity, despite the decreased net ion number density and the increased space charge effect. A simplified theoretical equation taking ion recombination as the primary ion loss factor was derived to link Poptimal with analyte concentration and electric field in PI-IMS, enabling a swift optimization of the PI-IMS performance. For example, compared to ambient pressure, PI-IMS at a Poptimal of 0.4 bar provided a signal intensity increment of more than 400% for 0.716 ppmv toluene and also expanded the linear dynamic range by more than two times. Revealing factors influencing the PI-IMS response would also benefit the applications of other chemical ionization sources in IMS or mass spectrometry (MS).