Your browser doesn't support javascript.
loading
Impact of intra- and extramedullary alignment on blood loss in total knee arthroplasty: a retrospective study.
Meißner, Nils; Frenzel, Alexander; Halder, Andreas M; Preis, Alexander; Sina, Jonas P; Schrednitzki, Daniel.
  • Meißner N; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, Waldhausstr. 44, 16766, Kremmen, Germany. Nils.Meissner@sana.de.
  • Frenzel A; Department of Orthopaedics, Carl-Thiem-Klinikum Cottbus, Thiemstraße 111, 03046, Cottbus, Germany.
  • Halder AM; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, Waldhausstr. 44, 16766, Kremmen, Germany.
  • Preis A; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, Waldhausstr. 44, 16766, Kremmen, Germany.
  • Sina JP; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, Waldhausstr. 44, 16766, Kremmen, Germany.
  • Schrednitzki D; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, Waldhausstr. 44, 16766, Kremmen, Germany.
Arch Orthop Trauma Surg ; 144(5): 1901-1905, 2024 May.
Article en En | MEDLINE | ID: mdl-38467938
ABSTRACT

BACKGROUND:

There is a scarcity of scientific data regarding the correlation between alignment techniques during total knee arthroplasty (TKA) and blood loss as well as transfusion rates. This study's hypothesis posited that intramedullary-aligned (IM) TKA exhibits higher blood loss and transfusion rates when contrasted with extramedullary-aligned (EM) TKA.

METHODS:

We conducted a retrospective examination of 883 patients who underwent total knee arthroplasty (TKA) in 2021 at a solitary orthopedic center in Germany. These patients were divided into two groups based on their tibial alignment technique extramedullary alignment and intramedullary tibial alignment.

RESULTS:

In the intramedullary tibial alignment (IM) group, we observed a blood loss of 0.91 L, while in the extramedullary tibial alignment (EM) group, the blood loss was 0.89 L. These values did not demonstrate a significant difference (p = 0.69). Transfusion rates were 0.99% in the IM group and 0.21% in the EM group, and there was no significant distinction between them (Chi-squared test p > 0.05).

CONCLUSION:

We observed no statistically significant variance in blood loss between the IM and EM groups. Likewise, there was no substantial disparity in transfusion rates between these groups. It can be concluded that the selection of a knee arthroplasty system incorporating either intramedullary tibial alignment or extramedullary alignment does not significantly impact blood loss.