Your browser doesn't support javascript.
loading
Does Meal or Water Intake Affect Ultrasound Attenuation Coefficient Estimate?
Ferraioli, Giovanna; De Silvestri, Annalisa; Barr, Richard G.
  • Ferraioli G; Dipartimento di Scienze Clinico-Chirurgiche, Diagnostiche e Pediatriche, University of Pavia, Pavia, Italy.
  • De Silvestri A; Clinical Epidemiology and Biometric Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy.
  • Barr RG; Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio, USA.
J Ultrasound Med ; 43(8): 1435-1440, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38646915
ABSTRACT

OBJECTIVES:

To assess whether meal or water intake may affect the measurement of the ultrasound (US) attenuation coefficient (AC) imaging, a parameter that is directly related to liver fat content.

METHODS:

The study was performed in two centers (Italy and USA). AC was obtained using the ATI algorithm implemented in the Aplio i-series US systems (Canon Medical Systems, Japan) by one operator at each center. Measurements were performed at baseline and 5, 15, 30, 45 minutes after drinking 500 mL of water (group 1), or 30, 45, 60, 90, 120 minutes after eating a meal of about 600 kcal (group 2). Multilevel generalized estimating equations for repeated measures were used for the statistical analysis to consider the clustered nature of the data.

RESULTS:

Twenty-six individuals were enrolled 11 (10 females; age, 43.7 ± 12.5 years) in Italy and 15 (10 females; age, 60.7 ± 6.3 years) in USA. At B-mode US, 10 (38.5%) had liver steatosis. The baseline AC values, in decibel/centimeter/megahertz, were 0.64 (0.12) in group 1 and 0.66 (0.13) in group 2. There was not any significant difference in AC values at every time-point after water or meal intake either in group 1 or group 2. This result did not change including sex, age, and skin-to-liver capsule into the models.

CONCLUSIONS:

The measurement of the AC, which is a biomarker of liver steatosis, does not require a fasting state and drinking water does not affect the result.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonografía / Ingestión de Líquidos / Hígado Límite: Adult / Female / Humans / Male / Middle aged País como asunto: America do norte / Europa Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonografía / Ingestión de Líquidos / Hígado Límite: Adult / Female / Humans / Male / Middle aged País como asunto: America do norte / Europa Idioma: En Año: 2024 Tipo del documento: Article