Your browser doesn't support javascript.
loading
Etching of Ag nanoparticles triggered bidirectional regulation for electrochemiluminescence ratiometric immunoassay.
Wang, Yu-Ling; Liu, Xiang-Mei; Ren, Shu-Wei; Cao, Jun-Tao; Liu, Yan-Ming.
  • Wang YL; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, NO. 237 in Nanhu Road, Xinyang, 464000, Henan, China.
  • Liu XM; Shandong Key Laboratory of Biochemical Analysis, Qingdao University of Science and Technology, Qingdao, 266042, China.
  • Ren SW; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, NO. 237 in Nanhu Road, Xinyang, 464000, Henan, China.
  • Cao JT; Xinyang Central Hospital, Xinyang, 464000, China.
  • Liu YM; College of Chemistry and Chemical Engineering, Xinyang Key Laboratory of Functional Nanomaterials for Bioanalysis, Xinyang Normal University, NO. 237 in Nanhu Road, Xinyang, 464000, Henan, China. jtcao11@163.com.
Anal Bioanal Chem ; 416(21): 4759-4767, 2024 Sep.
Article en En | MEDLINE | ID: mdl-38647693
ABSTRACT
A highly efficient ratiometric electrochemiluminescence (ECL) immunoassay was explored by bidirectionally regulating the ECL intensity of two luminophors. The immunoassay was conducted in a split-type mode consisting of an ECL detection procedure and a sandwich immunoreaction. The ECL detection was executed using a dual-disk glassy carbon electrode modified with two potential-resolved luminophors (g-C3N4-Ag and Ru-MOF-Ag nanocomposites), and the sandwich immunoreaction using glucose oxidase (GOx)-modified SiO2 nanospheres as labels was carried out in a 96-well plate. The Ag nanoparticles (NPs) acted as bifunctional units both for triggering the resonance energy transfer (RET) with g-C3N4 and for accelerating the electron transfer rate of the Ru-MOF-Ag ECL reaction. When the H2O2 catalyzed by GOx in the 96-well plate was transferred to the dual-disk glass carbon electrode, the doped Ag NPs in the two luminophors could be etched, thus destroying the RET between C3N4 and the accelerated reaction to Ru-MOF, resulting in an opposite trend in the ECL signal outputted from the dual disks. Using the ratio of the two signals for quantification, the constructed immunosensor for a model target, i.e. myoglobin, exhibited a low detection limit of 4.7 × 10-14 g/mL. The ingenious combination of ECL ratiometry, bifunctional Ag NPs, and a split-type strategy effectively reduces environmental and human errors, offering a more precise and sensitive analysis for complex samples.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Plata / Nanopartículas del Metal / Técnicas Electroquímicas / Límite de Detección / Glucosa Oxidasa / Mediciones Luminiscentes Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Plata / Nanopartículas del Metal / Técnicas Electroquímicas / Límite de Detección / Glucosa Oxidasa / Mediciones Luminiscentes Idioma: En Año: 2024 Tipo del documento: Article