Free-breathing high-resolution respiratory-gated radial stack-of-stars magnetic resonance imaging of the upper abdomen at 7 T.
Maatman, Ivo T; Schulz, Jenni; Ypma, Sjoerd; Block, Kai Tobias; Schmitter, Sebastian; Hermans, John J; Smit, Ewoud J; Maas, Marnix C; Scheenen, Tom W J.
  • Maatman IT; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Schulz J; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Ypma S; Erwin L Hahn Institute for MR Imaging, Essen, Germany.
  • Block KT; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Schmitter S; Department of Radiology, NYU Langone Health, New York, New York, USA.
  • Hermans JJ; Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Berlin, Germany.
  • Smit EJ; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Maas MC; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
  • Scheenen TWJ; Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.
NMR Biomed ; : e5180, 2024 May 22.
Article en En | MEDLINE | ID: mdl-38775032
ABSTRACT
Ultrahigh field magnetic resonance imaging (MRI) (≥ 7 T) has the potential to provide superior spatial resolution and unique image contrast. Apart from radiofrequency transmit inhomogeneities in the body at this field strength, imaging of the upper abdomen faces additional challenges associated with motion-induced ghosting artifacts. To address these challenges, the goal of this work was to develop a technique for high-resolution free-breathing upper abdominal MRI at 7 T with a large field of view. Free-breathing 3D gradient-recalled echo (GRE) water-excited radial stack-of-stars data were acquired in seven healthy volunteers (five males/two females, body mass index 19.6-24.8 kg/m2) at 7 T using an eight-channel transceive array coil. Two volunteers were also examined at 3 T. In each volunteer, the liver and kidney regions were scanned in two separate acquisitions. To homogenize signal excitation, the time-interleaved acquisition of modes (TIAMO) method was used with personalized pairs of B1 shims, based on a 23-s Cartesian fast low angle shot (FLASH) acquisition. Utilizing free-induction decay navigator signals, respiratory-gated images were reconstructed at a spatial resolution of 0.8 × 0.8 × 1.0 mm3. Two experienced radiologists rated the image quality and the impact of B1 inhomogeneity and motion-related artifacts on multipoint scales. The images of all volunteers showcased effective water excitation and were accurately corrected for respiratory motion. The impact of B1 inhomogeneity on image quality was minimal, underscoring the efficacy of the multitransmit TIAMO shim. The high spatial resolution allowed excellent depiction of small structures such as the adrenal glands, the proximal ureter, the diaphragm, and small blood vessels, although some streaking artifacts persisted in liver image data. In direct comparisons with 3 T performed for two volunteers, 7-T acquisitions demonstrated increases in signal-to-noise ratio of 77% and 58%. Overall, this work demonstrates the feasibility of free-breathing MRI in the upper abdomen at submillimeter spatial resolution at a magnetic field strength of 7 T.