Your browser doesn't support javascript.
loading
Permeation of a firearm cleaning solvent through disposable nitrile gloves.
Cribbs, Travis D; Que Hee, Shane S.
  • Cribbs TD; Department of Environmental Health Sciences and UCLA Center for Occupational and Environmental Health, Fielding School of Public Health, University of California Los Angeles, Los Angeles, California.
  • Que Hee SS; Department of Environmental Health Sciences and UCLA Center for Occupational and Environmental Health, Fielding School of Public Health, University of California Los Angeles, Los Angeles, California.
J Occup Environ Hyg ; 21(7): 494-503, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38838303
ABSTRACT
The objective was to study the interaction of the components of a complex liquid mixture on the permeation parameters of its constituents. A firearm cleaning solvent, Hoppes No. 9 Gun Bore Cleaner, was selected to challenge two varieties of disposable nitrile gloves, the thinnest (Kimberly-Clark Lavender) and thickest (Kimberly-Clark Blue), using the closed-loop ASTM F739 cell without recirculation and n-decane collection followed by quantitation of the permeated compounds using capillary gas chromatography-mass spectrometry. The thicker Blue glove resisted the permeation of Hoppe's relative to the thinner Lavender glove as shown by 3.2 times more mass permeated by the Lavender glove at 60 min despite the same standardized breakthrough times (7.5 ± 2.5 min). The kerosene fraction permeated faster at a much higher rate than expected. The Kimberly-Clark disposable nitrile glove chemical resistance guide lists a breakthrough time for kerosene of 82 min for Sterling disposable nitrile glove material. However, for Hoppe's the kerosene components appeared at the standardized breakthrough time. Mixture components that were reported by the glove manufacturer to quickly permeate the disposable nitrile material, such as ethanol, did not permeate at a rate slower than expected, indicative of a possible carrier function. A semiquantitative risk assessment confirmed the unacceptability of both gloves. Persons using personal protective equipment, such as gloves, may not be afforded the expected resistance to chemical permeation when chemicals are in a suitable mixture, hence enhancing the risk of exposure. More research is needed to produce better glove testing measures to ensure the safety of workers.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Permeabilidad / Solventes / Armas de Fuego / Guantes Protectores / Nitrilos Límite: Humans Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Permeabilidad / Solventes / Armas de Fuego / Guantes Protectores / Nitrilos Límite: Humans Idioma: En Año: 2024 Tipo del documento: Article