Your browser doesn't support javascript.
loading
Highly Sensitive Balloon-like Fiber Interferometer Based on Ethanol Coated for Temperature Measurement.
Ding, Xin; Lin, Qiao; Liu, Shen; Zhang, Lianzhen; Chen, Nan; Zhang, Yuping; Wang, Yiping.
  • Ding X; Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
  • Lin Q; Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.
  • Liu S; Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
  • Zhang L; Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
  • Chen N; School of Intelligent Manufacturing, Shandong Polytechnic College, Jining 272067, China.
  • Zhang Y; School of Electrical Engineering and Automation, Nantong University, Nantong 226019, China.
  • Wang Y; SINOPEC Research Institute of Safety Engineering Co., Ltd., Qingdao 266000, China.
Sensors (Basel) ; 24(11)2024 Jun 06.
Article en En | MEDLINE | ID: mdl-38894474
ABSTRACT
A highly sensitivity balloon-like fiber interferometer based on ethanol coating is presented in this paper. The Mach-Zehnder interferometer is formed by bending a single-mode fiber to a balloon-like structure and nested in the Teflon tube. Then, an ethanol solution was filled into the tube of the balloon-like fiber interferometer by the capillary effect. Due to the high sensitivity of the refractive index (RI) of ethanol solutions to temperature, when the external temperature varies, the optical path difference changes. The change in temperature can be detected by the shift in the interference spectrum. Limited by the size of the balloon-like structure, three kinds of these structures with different sensitive lengths were prepared to select the best parameters. The sensitive lengths were 10, 15 and 20 mm, respectively, and the RI detection performance of each structure in 10~26% NaCl solutions was investigated experimentally. The results show that when the sensitive length is 20 mm, the RI sensitivity of the sensor is the highest, which is 212.88 nm/RIU. Ultimately, the sensitive length filled with ethanol is 20 mm. The experimental results show that the temperature sensitivity of the structure is 1.145 nm/°C in the range of 28.1 °C~35 °C, which is 10.3 times higher than that of an unfilled balloon-like structure (0.111 nm/°C). The system has the advantages of low cost and easy fabrication, which can potentially be used in high-precision temperature monitoring processes.
Palabras clave