Your browser doesn't support javascript.
loading
Evaluation of peri-implant perfusion in patients who underwent avascular augmentation or microvascular reconstruction using laser Doppler flowmetry and tissue spectrophotometry: a prospective comparative clinical study.
Katz, Marie Sophie; Ooms, Mark; Winnand, Philipp; Heitzer, Marius; Peters, Florian; Kniha, Kristian; Hölzle, Frank; Modabber, Ali.
  • Katz MS; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany. mkatz@ukaachen.de.
  • Ooms M; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Winnand P; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Heitzer M; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Peters F; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Kniha K; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Hölzle F; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
  • Modabber A; Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelstraße 30, 52074, Aachen, Germany.
Clin Oral Investig ; 28(8): 431, 2024 Jul 17.
Article en En | MEDLINE | ID: mdl-39017918
ABSTRACT

OBJECTIVES:

The aim of this study was to evaluate the peri-implant perfusion, such as oxygen saturation, the relative amount of hemoglobin, and blood flow, in implants placed in pristine bone and avascular and microvascular grafts using a non-invasive measurement method. MATERIALS AND

METHODS:

A total of 58 patients with 241 implants were included. Among them, 106 implants were based in native bone (group I), 75 implants were inserted into avascular bone grafts (group II), and 60 implants were placed in microvascular bone grafts (group III). Gingival perfusion was measured using laser Doppler flowmetry and tissue spectrophotometry (LDF-TS). Implants with signs of gingival inflammation were excluded to analyze healthy implant perfusion in different bony envelopes.

RESULTS:

The mean values for oxygen saturation, relative hemoglobin levels, and blood flow did not differ significantly between the groups (p = 0.404, p = 0.081, and p = 0.291, respectively). There was no significant difference in perfusion between implants that were surrounded by mucosa and implants based within cutaneous transplants (p = 0.456; p = 0.628, and p = 0.091, respectively).

CONCLUSION:

No differences in perfusion were found between implants inserted into native bone and implants involving bone or soft tissue augmentation. However, implants based in avascular and microvascular transplants showed higher rates of peri-implant inflammation. CLINICAL RELEVANCE Peri-implant perfusion seems to be comparable for all implants after they heal, irrespective of their bony surroundings. Although perfusion does not differ significantly, other factors may make implants in avascular and microvascular transplants vulnerable to peri-implant inflammation.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrofotometría / Implantes Dentales / Flujometría por Láser-Doppler Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Espectrofotometría / Implantes Dentales / Flujometría por Láser-Doppler Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article