Finite element analysis of precise puncture vertebral augmentation in the treatment of different types of osteoporotic vertebral compression fractures.
Pan, Hongyu; Li, Hongtao; Liu, Tianzhu; Xiao, Changming; Li, Sen.
  • Pan H; Department of Spinal Surgery, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, Sichuan, China.
  • Li H; Department of Spinal Surgery, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, Sichuan, China.
  • Liu T; Neurological Disease Center, Zigong Fourth People's Hospital, Zigong, Sichuan, China.
  • Xiao C; Department of Spinal Surgery, The Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou, Sichuan, China.
  • Li S; Division of Spine Surgery, Department of Orthopedic Surgery, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China. jht187@163.com.
BMC Musculoskelet Disord ; 25(1): 599, 2024 Jul 30.
Article en En | MEDLINE | ID: mdl-39080550
ABSTRACT

BACKGROUND:

Osteoporosis vertebral compression fracture (OVCF) secondary to osteoporosis is a common health problem in the elderly population. Vertebral augmentation (VA) has been widely used as a minimally invasive surgical method. The transpedicle approach is commonly used for VA puncture, but sometimes, it is limited by the anatomy of the vertebral body and can not achieve good surgical results. Therefore, we propose the treatment of OVCF with precise puncture vertebral augmentation (PPVA). This study used finite element analysis to explore the biomechanical properties of PPVA in the treatment of osteoporotic vertebral compression fractures (OVCFs) with wedge, biconcave, and collapse deformities.

METHOD:

Three-dimensional finite element models of the fractured vertebral body and adjacent superior and inferior vertebral bodies were established using Computed Tomography (CT) data from patients with OVCF, both before and after surgery. Evaluate the stress changes of the wedged deformed vertebral body, biconcave deformed vertebral body, collapsed deformed vertebral body, and adjacent vertebral bodies before and after PPVA.

RESULT:

In vertebral bodies with wedge deformity and collapsed deformity, PPVA can effectively reduce the stress on the vertebral body but increases the stress on the vertebral body with biconcave deformity. PPVA significantly decreases the stress on the adjacent vertebral bodies of the wedge deformed vertebral body, and decreases the stress on the adjacent superior vertebral body of biconcave deformity and collapsed deformed vertebral bodies, but increases the stress on the adjacent inferior vertebral bodies. PPVA improves the stress distribution of the vertebral body and prevents high-stress areas from being concentrated on one side of the vertebral body.

CONCLUSION:

PPVA has shown positive surgical outcomes in treating wedge deformed and collapsed deformed vertebral bodies. However, its effectiveness in treating biconcave vertebral body is limited. Furthermore, PPVA has demonstrated favorable results in addressing adjacent superior vertebral body in three types of fractures.