Your browser doesn't support javascript.
loading
An evaluation of fusion status following lumbar fusion surgery utilizing multi-planar computed tomography.
Issa, Tariq Z; Lee, Yunsoo; Heard, Jeremy; Henry, Tyler W; McCurdy, Michael A; Siegel, Nicholas; Zaworksi, Caroline; Dambly, Julia; Canseco, Jose A; Hilibrand, Alan S; Vaccaro, Alexander R; Schroeder, Gregory D; Mangan, John; Lambrechts, Mark; Kepler, Christopher K.
  • Issa TZ; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA. tariq.issa@mountsinai.org.
  • Lee Y; Department of Orthopaedic Surgery, Mount Sinai Hospital, New York, NY, USA. tariq.issa@mountsinai.org.
  • Heard J; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Henry TW; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • McCurdy MA; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Siegel N; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Zaworksi C; Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, MD, USA.
  • Dambly J; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Canseco JA; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Hilibrand AS; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Vaccaro AR; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Schroeder GD; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Mangan J; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Lambrechts M; Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA, USA.
  • Kepler CK; Department of Orthopaedic Surgery, Washington University Hospital, St. Louis, MO, USA.
Eur Spine J ; 2024 Aug 03.
Article en En | MEDLINE | ID: mdl-39095491
ABSTRACT

PURPOSE:

To report the rate of fusion in a sample of patients undergoing lumbar fusion surgery and assess interrater reliability of computed tomography (CT)-based parameters for the assessment of fusion.

METHODS:

All adult patients who underwent lumbar fusion surgery from 2017 to 2021 were retrospectively identified. Patient demographics and surgical characteristics were collected through chart review of the electronic medical records. CT scans were reviewed independently by two attending spine surgeons and two spine fellows. Fusion was defined as evidence of bone bridging in any one of (1) posterolateral gutters, (2) facets, or (3) interbody (when applicable) on any CT views. Evidence of screw haloing was indicative of nonunion. Interrater reliability was determined using cohen's kappa. Afterwards, a consensus agreement for each component of fusion was reached between participants.

RESULTS:

The overall fusion rate among all procedures was 63/69 (91.3%). Overall 22/25 (88.0%) TLIF, 16/19 (84.2%) PLDF, 3/3 (100%) LLIF, and 22/22 (100%) circumferential fusions experienced a successful fusion. Interrater reliability was good for interbody fusion (k = 0.734) and moderate for all other measures (k = 0.561 for posterolateral fusion; k = 0.471 for facet fusion; k = 0.458 for screw haloing). Overall, interrater reliability as to whether a patient had a fusion or nonunion was moderate (k = 0.510).

CONCLUSION:

There was only moderate interrater reliability across most radiographic measures used in assessing lumbar fusion status. Reliability was highest when evaluating the presence of interbody fusion. The majority of fusions occurred across the facet joints.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2024 Tipo del documento: Article