The Application Value of Using Semiquantitative and Quantitative Parameters in Multimodal Ultrasound to Distinguish Between Benign and Malignant BI-RADS 4 Lesions.
Dai, Xi; Zhou, Xiao-Yu; Chen, Piao-Fei; Gong, Zhe-Li; Wang, Zhi-Ping; Wang, Di.
  • Dai X; Department of Ultrasound, Huangshan City People's Hospital, Huangshan, China.
  • Zhou XY; Department of Ultrasound, Huangshan City People's Hospital, Huangshan, China.
  • Chen PF; Department of Ultrasound, Huangshan City People's Hospital, Huangshan, China.
  • Gong ZL; Department of Ultrasound, Hunan Provincial People's Hospital (The First-Affiliated Hospital of Hunan Normal University), Changsha, China.
  • Wang ZP; Department of Ultrasound, Huangshan City People's Hospital, Huangshan, China.
  • Wang D; Department of Pathology, Huangshan City People's Hospital, Huangshan, China.
Ultrasound Q ; 40(3)2024 Sep 01.
Article en En | MEDLINE | ID: mdl-39105688
ABSTRACT
ABSTRACT This study aims to explore the value of real-time strain elastography (RTE) and contrast-enhanced ultrasonography (CEUS) in the diagnosis of breast BI-RADS 4 lesions. It collected 85 cases (totaling 85 lesions) diagnosed with breast BI-RADS 4 through routine ultrasound from October 2020 to December 2022 in Huangshan City People's Hospital. All lesions underwent RTE and CEUS examination before surgery, and the ImageJ software was used to measure the periphery of lesion images in the enhancement peak mode and grayscale mode to calculate the contrast-enhanced ultrasound area ratio. The diagnostic capabilities of single-modal and multimodal ultrasound examination for the malignancy of breast BI-RADS 4 lesions were compared using the receiver operating characteristic curve; the Spearman correlation analysis was adopted to evaluate the correlation between multimodal ultrasound and CEUS area ratio. As a result, among the 85 lesions, 51 were benign, and 34 were malignant. The areas under the curve (AUCs) of routine ultrasound (US), US + RTE, US + CEUS, and US + RTE + CEUS were 0.816, 0.928, 0.953, and 0.967, respectively, with the combined method showing a higher AUC than the single application. The AUC of the CEUS area ratio diagnosing breast lesions was 0.888. There was a strong positive correlation (r = 0.819, P < 0.001) between the diagnostic performance of US + RTE + CEUS and the CEUS area ratio. In conclusion, based on routine ultrasound, the combination of RTE and CEUS can further improve the differential diagnosis of benign and malignant lesions in breast BI-RADS 4.