Your browser doesn't support javascript.
loading
Cell culture quality control by rapid isoenzymatic characterization.
In Vitro ; 19(1): 16-24, 1983 Jan.
Article en En | MEDLINE | ID: mdl-6401685
ABSTRACT
Procedures that involve cell cultures require careful quality control to avoid inter- and intraspecies contamination. We have developed an electrophoresis technique that can be used routinely in cell culture laboratories to monitor cell line integrity. The method involves the isoenzymatic separation of nine polymorphic enzymes, three of which can be used for cell line species determinations and seven of which can be used for human cell line characterizations. Examples of how the system has been applied to both inter- and intraspecies identifications are described. The routine application of this protocol would be a valuable asset for laboratories concerned with establishing effective cell culture quality control.
Asunto(s)
Search on Google
Banco de datos: MEDLINE Asunto principal: Línea Celular / Técnicas Citológicas / Isoenzimas Límite: Animals / Humans Idioma: En Año: 1983 Tipo del documento: Article
Search on Google