Effect of time on liver clearance of technetium-99m-tetrofosmin in patients with acute chest pain: when should imaging begin?
Mann, A; Ahlberg, A W; White, M P; Cross, D M; Piriz, J; Morris, R S; Heller, G V.
  • Mann A; Nuclear Cardiology Laboratory, Hartford Hospital, CT 06102, USA.
J Nucl Med Technol ; 26(3): 186-90, 1998 Sep.
Article en En | MEDLINE | ID: mdl-9755438
ABSTRACT

OBJECTIVE:

Due to stable myocardial retention and technetium imaging characteristics, 99mTc-tetrofosmin has been considered potentially useful for acute chest pain imaging. Tetrofosmin also has favorable biokinetics with reported rapid liver clearance, 5 min poststress and 30-45 min post-rest injection. Since comparable data are not available, the effect of time on liver clearance was evaluated in patients with acute chest pain.

METHODS:

One hundred six patients received an intravenous injection of 25-30 mCi 99mTc-tetrofosmin to evaluate acute chest pain. SPECT imaging was performed 15-120 min after injection of the tracer. Patient images were grouped according to the time of acquisition after acute injection 15-30 min, 31-45 min, 46-60 min, 61-90 min and > 90 min. Quantitative analysis was performed of a similar anterior projection for each patient consisting of 6 X 6-pixel region of interest over the myocardium and adjacent liver. Average counts per pixel were determined and a heart/liver (H/Li) ratio was calculated.

RESULTS:

The mean H/Li ratio was < 1.0 for patient images acquired 15-45 min after injection, and > 1.0 for patient images acquired after 45 min. The difference was statistically significant (p < 0.05).

CONCLUSION:

Quantitative analysis suggests that the optimal imaging time should be at least 45 min after the injection of 99mTc-tetrofosmin to allow adequate liver clearance before image acquisition of acute chest pain syndromes.
Asunto(s)
Search on Google
Banco de datos: MEDLINE Asunto principal: Compuestos Organofosforados / Compuestos de Organotecnecio / Tomografía Computarizada de Emisión de Fotón Único / Radiofármacos / Angina de Pecho / Hígado Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 1998 Tipo del documento: Article
Search on Google
Banco de datos: MEDLINE Asunto principal: Compuestos Organofosforados / Compuestos de Organotecnecio / Tomografía Computarizada de Emisión de Fotón Único / Radiofármacos / Angina de Pecho / Hígado Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 1998 Tipo del documento: Article