Analysis of the associated complication with circulatory support device / 中华急诊医学杂志
Chinese Journal of Emergency Medicine
; (12): 867-869, 2008.
Article
en Zh
| WPRIM
| ID: wpr-399287
Biblioteca responsable:
WPRO
ABSTRACT
Objetctive To summarize the associated complications with circulatory support device,and provide reference for chnical practice.Method A total of 8306 consecutive patients who underwent open heart surgery,in Department of Post-operation Intensive Care Unit of the Cardiac Surgery,Anzhen Hospital,Capital Medical University,was retrospectively studied from January 2005 to February 2007.And the clinical data of 246 patients including 63 female and 183 male patients with mean age 56.7±14.2 years supported with various circulatory support devices for perioperative cardiorespiratory function failure in ICU were analyzed.Left ventricular assist device (LVAD) was used in 3 patients by the cannulation of the left alritan and ascending aorta.The extracorporeal membrane oxygenation(ECMO) was established in 48 patients for postoperative cardiorespiratory function failure.The vencarterial bypass was established by cannulation of the right atrium in 41 patients and femoral artery and of venovenons in 2 patients,and of the right atrium and ascending aorta in 5 cases,lntra-aortic balloon pumping(I-ABP)was performed via the femoral artery either percutaneonsly by the Seldinger technique in 195 patients.The cardiac operations included coronary artery bypass grafting (n=170),coronary artery bypass grafting with romoldingof left ventricle (n = 22),coronary artery bypass grafting with valvular operation (n=10),valvular operation (n=27),heart transplantation(n=8),correction of congenital heart defects(n=6),aortic operations(n=2).The duration of circulatory support ranged from 4 to 451 hours.Correlative complications of 3 kinds of circulatory support device were compared and repair of ventricular septal perforation in the wake of acute myocardial infarction (n=1).Results Seventy-eight (31.7%) patients died.Seventy-one(28.9% ) patients devdoped various complications including infection(n=27),renal failure required renal rephcement therapy (n=27),re-exploration for bleeding(n=24),haemolysis(n=6),limb ischemia(n=15),neurological complications(n=6),oxygenator failure(n=7) Conchusions The improvement of management to reduce complications may result in improved outcomes of patients supported with circulatory support devices.
Texto completo:
1
Banco de datos:
WPRIM
Idioma:
Zh
Año:
2008
Tipo del documento:
Article