ObjectiveTo investigate the value of double-balloon endoscopy for the diagnosis of small bowel Crohn disease(CD).MethodsData of 141 patients with suspected CD undergoing double-balloon endoscopy were reviewed.Diagnosis was made based on pathological,endoscopic findings and clinic follow-up results.Detection rates and diagnosis rates of small bowel CD were compared by double-balloon enteroscopy,CT enterography and capsule endoscopy.ResultsThe detection and diagnosis rates of small bowel CD by double-balloon endoscopy were 90.8% ( 128/141 ) and 98.4% ( 126/128),respectively.These two variables by CT enterography were 76.0% (19/25) and 89.5% (17/19),and those by capsule endoscopy were 60.0% (15/25) and 93.3% (14/15).ConclusionDouble balloon enteroscopy has high application value for the diagnosis of small bowel CD.For those contraindicated with endoscopy,CT enterography can be considered as a preferred auxiliary diagnostic modality.