Your browser doesn't support javascript.
loading
Application of aqueous two-phase micellar system to improve extraction of adenoviral particles from cell lysate
Molino, João Vitor Dutra; Lopes, Andre Moreni; Viana Marques, Daniela de Araujo; Mazzola, Priscila Gava; da Silva, Joas Lucas; Hirata, Mario Hiroyuki; Hirata, Rosario Dominguez Crespo; Gatti, Maria Silvia Viccari; Pessoa, Adalberto.
Afiliação
  • Molino, João Vitor Dutra; School of Pharmaceutical Sciences. University of São Paulo. São Paulo. BR
  • Lopes, Andre Moreni; School of Pharmaceutical Sciences. São Paulo State University. Araraquara. BR
  • Viana Marques, Daniela de Araujo; University of Pernambuco. Serra Talhada. BR
  • Mazzola, Priscila Gava; Faculty of Pharmaceutical Sciences. University of Campinas. Campinas. BR
  • da Silva, Joas Lucas; School of Pharmaceutical Sciences. University of São Paulo. São Paulo. BR
  • Hirata, Mario Hiroyuki; School of Pharmaceutical Sciences. University of São Paulo. São Paulo. BR
  • Hirata, Rosario Dominguez Crespo; School of Pharmaceutical Sciences. University of São Paulo. São Paulo. BR
  • Gatti, Maria Silvia Viccari; Institute of Biology. University of Campinas. Campinas. BR
  • Pessoa, Adalberto; School of Pharmaceutical Sciences. University of São Paulo. São Paulo. BR
Biotechnol. appl. biochem ; 65(3): 381-389, 2018. ilus, tab
Article em En | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1060882
Biblioteca responsável: BR79.1
Localização: BR79.1
ABSTRACT
Viral vectors are important in medical approaches, such as disease prevention and gene therapy, and their production depends on efficient prepurification steps. In the present study, an aqueous two-phase micellar system (ATPMS) was evaluated to extract human adenovirus type 5 particles from a cell lysate. Adenovirus was cultured in human embryonic kidney 293 (HEK-293) cells to a concentration of 1.4 × 1010 particles/mL. Cells were lysed, and the system formed by direct addition of Triton X-114 in a 23 full factorial design with center points. The systems were formed with Triton X-114 at a final concentration of 1.0, 6.0, and 11.0% (w/w), cell lysate pH of 6.0, 6.5, and 7.0, and incubation temperatures at 33, 35, and 37 °C. Adenovirus particles recovered from partition phases were measured by qPCR. The best system condition was with 11.0% (w/w) of Triton X-114, a cell lysate pH of 7.0, and an incubation temperature at 33 °C, yielding 3.51 × 1010 adenovirus particles/mL, which increased the initial adenovirus particles concentration by 2.3-fold, purifying it by 2.2-fold from the cell lysate, and removing cell debris. In conclusion, these results demonstrated that the use of an aqueous two-phase micellar system in the early steps of downstream processing could improve viral particle extraction from cultured cells while integrating clarification, concentration, and prepurification steps.
Assuntos
Palavras-chave
Buscar no Google
Coleção SES: Producao_cientifica Base de dados: SES-SP / SESSP-IDPCPROD Assunto principal: Água / Vetores Genéticos Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article
Buscar no Google
Coleção SES: Producao_cientifica Base de dados: SES-SP / SESSP-IDPCPROD Assunto principal: Água / Vetores Genéticos Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article