Motivos de retirada e principais complicações em cateteres venosos periféricos: estudo descritivo / Characterization of peripheral venous catheter use in a unit specialized in adolescent health / Caracterización del uso de catéter venoso periférico en una unidad especializada en salud adolescen-te
Ferreira, Myllela Gonçalves; Peres, Ellen Marcia; Leite, Dayana Carvalho; Peixoto, Isabela Costa; Pires, Bruna Maiara Ferreira Barreto; Gomes, Helena Ferraz.
Afiliação
  • Ferreira, Myllela Gonçalves; Universidade do Estado do Rio de Janeiro. Rio de Janeiro, RJ. BR
  • Peres, Ellen Marcia; Universidade do Estado do Rio de Janeiro. Rio de Janeiro, RJ. BR
  • Leite, Dayana Carvalho; Universidade do Estado do Rio de Janeiro. Rio de Janeiro, RJ. BR
  • Peixoto, Isabela Costa; Universidade do Estado do Rio de Janeiro. Rio de Janeiro, RJ. BR
  • Pires, Bruna Maiara Ferreira Barreto; Universidade Federal Fluminense. Niterói, RJ. BR
  • Gomes, Helena Ferraz; Universidade do Estado do Rio de Janeiro. Rio de Janeiro, RJ. BR
Rev. enferm. atenção saúde ; 12(1): 202366, nov.-fev. 2023. tab
Article em En, Es, Pt | BDENF | ID: biblio-1435167
Biblioteca responsável: BR394.1
Localização: BR394.1
RESUMO

Objetivo:

avaliar a cateterização venosa periférica em uma unidade especializada em saúde do adolescente e identificar a correlação dos motivos de retiradas com número de tentativas de punção e calibre do cateter sobre agulha.

Método:

estudo descritivo, de abordagem quantitativa.

Resultados:

Ocorreram 67 punções venosas, predominando o gauge 22 (76,1%). Nos motivos de retirada destacam-se a forma eletiva em 44,8%, seguido de remoção acidental em 31,3%. Quanto às complicações ocorridas 43,7% foram por obstrução do cateter. Quanto maior ao número de tentativas e maior chance de flebite, observou-se correlação moderada positiva (0,494) com p<0,001, e com relação ao maior calibre e maior chance de flebite, identificou-se correlação forte positiva (0,575) com p<0,001.

Conclusão:

reforça-se a necessidade da implementação das boas práticas relacionadas à manutenção desses dispositivos, capacitação da equipe e criação de protocolos e bundles voltados para a prática clínica. (AU).
ABSTRACT

Objective:

evaluate peripheral venous catheterization in a specialized adolescent health unit and and identify the correlation of reasons for withdrawals with the number of puncture attempts and caliber of the catheter over the needle.

Method:

descriptive study with a quantitative approach.

Results:

13 (56,5%) were male, aged between 15 and 17 years (82,6%). Regarding medical diagnosis by systems, rheumatology stands out in 11 adolescents (47,8%). There were 67 venous punctures, with the 22 gauge predominating (76.1%). In terms of withdrawal, the elective form stands out in 44,8%, followed by accidental removal in 31,3%. Regarding complications, 43,7% were due to catheter obstruction. Also, the greater the number of attempts, the greater the chance of phlebitis, moderate positive correlation (0.494) with p <0.001 and the larger the caliber, the greater the chance of phlebitis, strong positive correlation (0.575) with p <0.001.

Conclusion:

the need to implement good practices related to the maintenance of these devices, staff training and the creation of protocols and bundles aimed at clinical practice is reinforced. (AU).
RESUMEN

Objetivo:

evaluar el cateterismo venoso periférico en una unidad especializada de salud del adolescente y identificar la correlación de los motivos de los retiros con el número de intentos de punción y el calibre del catéter sobre la aguja.

Método:

estudio descriptivo con abordaje cuantitativo.

Resultados:

13 (56,5%) eran hombres, con edades comprendidas entre 15 y 17 años (82,6%). En cuanto al diagnóstico médico por sistemas, destacala reumatología en 11 adolescentes (47,8%). Se realizaron 67 punciones venosas, predominando el calibre 22 (76,1%). En cuanto a la baja, destaca la forma electiva en un 44,8%, seguida de la baja accidental en un 31,3%. En cuanto a las complicaciones, el 43,7% se debió a la obstrucción del catéter. Asimismo, a mayor número de intentos, mayor probabilidad de flebitis, correlación positiva moderada (0,494) con p <0,001 y a mayor calibre, mayor probabilidad de flebitis, fuerte correlación positiva (0,575) con p <0,001.

Conclusión:

se refuerza la necesidad de implementar buenas prácticas relacionadas con el mantenimiento de estos dispositivos, la formación del personal y la creación de protocolos y paquetes dirigidos a la práctica clínica. (AU).