Evaluation of the physicochemical properties of silicone- and epoxy resin-based root canal sealers
Camargo, Rafael Verardino de; Silva-Sousa, Yara Terezinha Corrêa; Rosa, Rodrigo Presotto Ferreira da; Mazzi-Chaves, Jardel Francisco; Lopes, Fabiane Carneiro; Steier, Liviu; Sousa-Neto, Manoel Damião.
Afiliação
  • Camargo, Rafael Verardino de; Universidade de São Paulo. School of Dentistry of Ribeirão Preto. Department of Restorative Dentistry. Ribeirão Preto. BR
  • Silva-Sousa, Yara Terezinha Corrêa; Universidade de Ribeirão Preto. Faculty of Dentistry. Ribeirão Preto. BR
  • Rosa, Rodrigo Presotto Ferreira da; Universidade de São Paulo. School of Dentistry of Ribeirão Preto. Department of Restorative Dentistry. Ribeirão Preto. BR
  • Mazzi-Chaves, Jardel Francisco; Universidade de São Paulo. School of Dentistry of Ribeirão Preto. Department of Restorative Dentistry. Ribeirão Preto. BR
  • Lopes, Fabiane Carneiro; Universidade de São Paulo. School of Dentistry of Ribeirão Preto. Department of Restorative Dentistry. Ribeirão Preto. BR
  • Steier, Liviu; The University of Warwick. Warwick Medical School. Coventry. GB
  • Sousa-Neto, Manoel Damião; Universidade de São Paulo. School of Dentistry of Ribeirão Preto. Department of Restorative Dentistry. Ribeirão Preto. BR
Braz. oral res. (Online) ; 31: e72, 2017. tab
Article em En | LILACS | ID: biblio-952078
Biblioteca responsável: BR1.1
ABSTRACT
Abstract To assess the physicochemical properties of AH Plus, GuttaFlow 2, GuttaFlow BioSeal, and MM Seal, five samples of each root canal sealer were evaluated to determine their setting time (ST), dimensional change (DC), solubility (SL), flow (FL), and radiopacity (RD) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The distilled and deionized water obtained from the SL test were subjected to atomic absorption spectrometry to observe the presence of Ca2+, K+, and Na+ ions. Statistical analysis was performed by using one-way ANOVA and Tukey-Kramer tests (p < 0.05). The following results were obtained ST (min) (AH Plus 463.6 ± 13.22; GuttaFlow 2 24.35 ± 2.78; GuttaFlow Bioseal 17.4 ± 0.55; MM Seal 47.60 ± 4.39), DC (%) (AH Plus 0.06 ± 0.12; GuttaFlow 2 −26.06 ± 1.24; GuttaFlow Bioseal 2.10 ± 1.47; MM Seal 8.47 ± 2.41), SL (%) (AH Plus 0.41 ± 0.21; GuttaFlow 2 5.13 ± 4.11; GuttaFlow Bioseal 3.03 ± 1.05; MM Seal 0.94 ± 0.17), FL (mm) (AH Plus 36.42 ± 0.40; GuttaFlow 2 36.44 ± 0.05; GuttaFlow Bioseal 35.4 ± 0.03; MM Seal 52.75 ± 0.60), and RD (mmAl) (AH Plus 7.52 ± 1.59; GuttaFlow 2 6.85 ± 0.14; GuttaFlow Bioseal 7.02 ± 0.18; MM Seal 3.32 ± 0.90). ST, DC, SL, FL, and RD showed statistical differences among the root canal sealers (p < 0.05). As AH Plus showed the lowest DC and SL values (p < 0.05), the findings indicate that this sample is the only sealer conforming to ANSI/ADA standards.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: LILACS Assunto principal: Materiais Restauradores do Canal Radicular / Silicones / Dimetilpolisiloxanos / Resinas Epóxi / Guta-Percha Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: LILACS Assunto principal: Materiais Restauradores do Canal Radicular / Silicones / Dimetilpolisiloxanos / Resinas Epóxi / Guta-Percha Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article