Your browser doesn't support javascript.
loading
Estudio prospectivo sobre la efectividad de una minibanda suburetral en el tratamiento de la incontinencia urinaria de esfuerzo / Prospective study of the effectiveness of the tension-free vaginal tape mini-sling in the treatment of stress urinary incontinence
Guerra, Sandra; Cuesta, María del Carmen; Marín, Juan Manuel; Lete, Iñaki.
Afiliação
  • Guerra, Sandra; Hospital Universitario Araba-Santiago. Vitoria. España
  • Cuesta, María del Carmen; Hospital Universitario Araba-Santiago. Vitoria. España
  • Marín, Juan Manuel; Universidad del País Vasco. Hospital Universitario Araba-Santiago. Vitoria. España
  • Lete, Iñaki; Universidad del País Vasco. Hospital Universitario Araba-Santiago. Vitoria. España
Prog. obstet. ginecol. (Ed. impr.) ; 56(10): 502-507, dic. 2013. tab, ilus
Article em Es | IBECS | ID: ibc-116898
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Evaluar la eficacia de la minibanda vaginal libre de tensión (TVT-S) en el tratamiento de la incontinencia urinaria de esfuerzo (IUE). Material y método. Estudio prospectivo de 170 pacientes con IUE a las que se insertó una minibanda TVT-S y fueron seguidas durante un mínimo de 24 meses. Se evaluaron la curación objetiva de la IUE, mediante exploración clínica, y la curación subjetiva, mediante el cuestionario ICIQ-SF. Resultados. El análisis final se realizó sobre 137 pacientes. La tasa de curación objetiva fue del 84% y la subjetiva del 91,2%. Se produjeron 7 complicaciones intraoperatorias (4,11%) y 5 extrusiones de la malla (3,6%) durante el periodo de seguimiento. Conclusiones. En nuestra serie la minibanda TVT-S presenta una tasa aceptable de curación de la incontinencia urinaria de esfuerzo, pero inferior a la tasa de curación publicada para las bandas TVT y TVT-O (AU)
ABSTRACT

Objectives:

To assess the efficacy of the tension-free vaginal tape mini-sling (TVT-S) to treat stress urinary incontinence (SUI) in women. Material and

method:

We performed a prospective study of 170 patients who underwent TVT-S insertion and who were followed-up for at least 24 months. Both the objective and subjective cure rate were evaluated using clinical examination and the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF).

Results:

The final number of assessed women was 137. The objective cure rate was 84% and the subjective cure rate was 91.2%. There were 7 complications during the surgery and 5 cases of mesh exposure (3.6%) during the follow-up period.

Conclusions:

In our experience, the TVT-S cure rate for SUI is acceptable but is lower than the published cure rate for tension-free transvaginal tape (TVT) and tension-free transvaginal tape obturator (TVT-O) (AU)
Assuntos
Buscar no Google
Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos em Ginecologia / Incontinência Urinária por Estresse / Complicações Intraoperatórias Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: Es Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos em Ginecologia / Incontinência Urinária por Estresse / Complicações Intraoperatórias Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Female / Humans Idioma: Es Ano de publicação: 2013 Tipo de documento: Article