Your browser doesn't support javascript.
loading
Distrofia de Fuchs asociada a queratotomía radial: ¿queratoplastia penetrante o lamelar? / Fuchs' dystrophy associated with radial keratotomy: Lamellar or perforating keratoplasty?
Rodriguez-Ausin, P; Antolin-Garcia, D; Santamaria Garcia, L; Blazquez-Fernandez, AB.
Afiliação
  • Rodriguez-Ausin, P; Hospital Universitario de Torrejón de Ardoz. Torrejón de Ardoz. España
  • Antolin-Garcia, D; Hospital Universitario de Torrejón de Ardoz. Torrejón de Ardoz. España
  • Santamaria Garcia, L; Hospital Universitario de Torrejón de Ardoz. Torrejón de Ardoz. España
  • Blazquez-Fernandez, AB; Hospital Universitario de Torrejón de Ardoz. Torrejón de Ardoz. España
Arch. Soc. Esp. Oftalmol ; 92(5): 237-240, mayo 2017.
Article em Es | IBECS | ID: ibc-162628
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
CASO CLINICO: Paciente de 70 años que acude con queratotomía radial, signos de distrofia de Fuchs con edema central y catarata. Se realiza cirugía en 2 tiempos: facoemulsificación e implante de lente intraocular y 4 meses después DSAEK (descemet stripping automatized endothelial keratoplasty) en ambos ojos sucesivamente sin complicaciones, salvo edema macular cistoide recurrente en ambos ojos. La agudeza visual corregida final es 20/40 en ambos ojos y el paciente se encuentra satisfecho. DISCUSIÓN: Ante coexistencia de queratotomía radial y disfunción endotelial, la DSAEK constituye una alternativa a la queratoplastia penetrante si no se detecta ectasia corneal ni opacidad estromal significativa
ABSTRACT
CASE REPORT: A 70 year-old male patient with a history of radial keratotomy suffering from Fuchs' dystrophy and a cataract. The patient received a two-step surgery: lens phacoemulsification and intraocular lens implant, followed by descemet stripping automated endothelial keratoplasty in both eyes, four months later. There were no complications apart from a recurrent cystoid macular oedema in both eyes. The best corrected visual acuity was 20/40 both eyes, and the patient was satisfied. DISCUSSION: Descemet stripping automated endothelial keratoplasty may be considered as an alternative to penetrating keratoplasty in the case of endothelial dysfunction and radial keratotomy in patients with no corneal ectasia or significant stromal opacity
Assuntos
Buscar no Google
Base de dados: IBECS Assunto principal: Ceratotomia Radial / Edema da Córnea / Distrofia Endotelial de Fuchs Tipo de estudo: Risk_factors_studies Limite: Aged / Humans / Male Idioma: Es Ano de publicação: 2017 Tipo de documento: Article
Buscar no Google
Base de dados: IBECS Assunto principal: Ceratotomia Radial / Edema da Córnea / Distrofia Endotelial de Fuchs Tipo de estudo: Risk_factors_studies Limite: Aged / Humans / Male Idioma: Es Ano de publicação: 2017 Tipo de documento: Article