Eficiência da desinfecção dos cones de guta-percha na endodontia / Disinfection efficiency of gutta-percha cones in endodontics
Rev. Assoc. Paul. Cir. Dent
; 68(3): 214-218, jul.-set. 2014. ilus, tab
Article
em Pt
| LILACS
| ID: lil-729354
Biblioteca responsável:
BR97.1
RESUMO
Os objetivos do presente estudo foram verificar a contaminação dos cones de guta-percha presentes em embalagens lacradas, bem como dos que estavam sendo usados em consultórios pelos cirurgiões dentistas (CO); e avaliar se protocolos de desinfecção com agentes antimicrobianos, são eficientes. Os cones de guta-percha foram coletados em 30 consultórios particulares e os CD forneciam dados referentes ao uso ou não de protocolos de desinfecção. Os cones de guta-percha das embalagens lacradas não passaram por nenhum tipo de desinfecção e foram imediatamente transferidos para tubos contendo BHI caldo. Os protocolos de desinfecção, quando existiam, foram simulados e depois os cones foram transferidos para os tubos de BHI caldo. Todas as amostras foram incubadas a 37°C e a leitura feita após 48 horas. A presença de contaminação foi verificada através da turvação do meio de cultura. Os resultados mostraram ausência de contaminação em todos os cones das caixas lacradas ou que foram coletados de consultórios. Os autores concluíram que apesar dos cones se apresentarem sem contaminação, o protocolo de desinfecção previamente à obturação, deveria ser adotado por todos.
ABSTRACT
The aims of this study were to evaluate the contamination of gutta percha cones in sealed packages, as well as those packages which were being used by dentists (D) in private clinical after opening. Additionally, it was evaluated if disinfection protocols with antimicribial agent are efficient. The gutta-percha points were collected from 30 private offices and data about the use or not of disinfection protocols were provided. The sealed packages of gutta-percha were immediately transferred to tubes containing BHI broth tubes. The gutta-percha from opening packages were transferred to BHI broth tubes or were first passed for disinfection protocols and then transferred for the tubes. Ali samples were incubated at 37°C and they were analyzed after 48 hours. The presence of contamination was measured by the turbidity of the culture medium. The results showed no contamination in ali gutta-percha cones. The authors concluded that although the cones had no contamination, the disinfection protocol, before root canal obtura tion, should be adopted.
Buscar no Google
Base de dados:
LILACS
Assunto principal:
Obturação do Canal Radicular
/
Hipoclorito de Sódio
/
Desinfecção
Tipo de estudo:
Guideline
Idioma:
Pt
Ano de publicação:
2014
Tipo de documento:
Article