Your browser doesn't support javascript.
loading
Drew-Anderson technique attenuates systemic inflammatory response syndrome and improves respiratory function after coronary artery bypass grafting.
Richter, J A; Meisner, H; Tassani, P; Barankay, A; Dietrich, W; Braun, S L.
Afiliação
  • Richter JA; Department of Anesthesiology, German Heart Center, Technical University of Munich. richter@dhm.mhn.de
Ann Thorac Surg ; 69(1): 77-83, 2000 Jan.
Article em En | MEDLINE | ID: mdl-10654491
BACKGROUND: Cardiopulmonary bypass causes inflammatory reactions leading to organ dysfunction postoperatively. This study was undertaken to determine whether using patients' own lungs as oxygenator in a bilateral circuit (Drew-Anderson Technique) could reduce systemic inflammatory response to cardiopulmonary bypass, improving patients clinical outcome following coronary artery bypass grafting. METHODS: A prospective randomized controlled trial involving 30 patients, divided in two groups of 15 patients each, undergoing elective coronary artery bypass grafting, was undertaken. In the Drew-group bilateral extracorporeal circulation using patient's lung as oxygenator was performed. The other patients served as control group, where standard cardiopulmonary bypass procedure was used. RESULTS: Pro-inflammatory and anti-inflammatory mediators were measured. Peak concentrations of proinflammatory interleukin-6, interleukin-8, were significantly lower in 15 patients undergoing Drew-Anderson Technique compared with the concentrations measured in 15 patients treated with standard cardiopulmonary bypass technique. Differences in patient recovery were analyzed with respect to time of intubation, blood loss, intrapulmonary shunting, oxygenation, and respiratory index. In patients undergoing uncomplicated coronary artery bypass grafting procedures bilateral extracorporeal circulation using the patients' own lung as oxygenator provided significant biochemical and clinical benefit in comparison to the standard cardiopulmonary bypass procedure. CONCLUSIONS: This prospective randomized clinical study has demonstrated that exclusion of an artificial oxygenator from cardiopulmonary bypass circuit significantly decreases the activation of inflammatory reaction, and that interventions that attenuate this response may result in more favorable clinical outcome.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Fenômenos Fisiológicos Respiratórios / Ponte de Artéria Coronária / Síndrome de Resposta Inflamatória Sistêmica / Circulação Extracorpórea / Pulmão Tipo de estudo: Clinical_trials / Observational_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2000 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Fenômenos Fisiológicos Respiratórios / Ponte de Artéria Coronária / Síndrome de Resposta Inflamatória Sistêmica / Circulação Extracorpórea / Pulmão Tipo de estudo: Clinical_trials / Observational_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2000 Tipo de documento: Article