Positron emission tomography scan in the diagnosis and follow-up of aortitis of the thoracic aorta.
Derdelinckx, I; Maes, A; Bogaert, J; Mortelmans, L; Blockmans, D.
Afiliação
  • Derdelinckx I; Department of Cardiology, Gasthuisberg University Hospital, Leuven, Belgium.
Acta Cardiol ; 55(3): 193-5, 2000 Jun.
Article em En | MEDLINE | ID: mdl-10902045
ABSTRACT
We report a case of a 62-year-old female patient with an inflammatory reaction of the thoracic aortic wall. The diagnosis was made by computed tomographic (CT) scan, magnetic resonance imaging (MRI) and positron emission tomographic scan with 18-fluorodeoxyglucose (FDG-PET). The patient was treated with corticosteroids. The inflammatory parameters as well as FDG-uptake on PET scan returned to normal. Due to its aspecific presentation, the diagnosis of aortitis is often hard to establish. With this case the possible role of FDG-PET scan as a valuable tool in the diagnosis and monitoring of this inflammatory aortic disorder was demonstrated.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Aorta Torácica / Aortite / Tomografia Computadorizada de Emissão Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2000 Tipo de documento: Article