Propranolol in hypertensive dialysis patients: efficacy and compliance.
Clin Pharmacol Ther ; 18(5 Pt 1): 606-12, 1975 Nov.
Article em En | MEDLINE | ID: mdl-1183140
ABSTRACT
The effect of propranolol therapy on plasma renin activity and blood pressure control was evaluated in 35 uremic patients receiving intermittent center-based outpatient hemodialysis. Patients were determined to be either compliant or noncompliant with therapy based on the steady-state predialysis plasma propranolol concentration. Noncompliance occurred with remarkable frequency and was associated with persistent hyperreninemia and poorly controlled hypertension. Blood pressure control was significantly better in compliant patients, in whom plasma renin activity was generally, but not universally, suppressed. Propranolol can be effectively used in the management of hypertensive dialysis patients, but steady-state plasma propranolol levels should be measured to assess compliance in patients apparently refractory to treatment.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Propranolol / Uremia / Diálise Renal / Cooperação do Paciente / Hipertensão Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1975 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Propranolol / Uremia / Diálise Renal / Cooperação do Paciente / Hipertensão Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1975 Tipo de documento: Article