Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer.
Soete, Guy; Van de Steene, Jan; Verellen, Dirk; Vinh-Hung, Vincent; Van den Berge, Dirk; Michielsen, Dirk; Keuppens, Frans; De Roover, Patricia; Storme, Guy.
Afiliação
  • Soete G; Department of Radiotherapy, Academic Hospital Free University of Brussels, Brussels, Belgium. guy.soete@az.vub.ac.be
Int J Radiat Oncol Biol Phys ; 52(3): 694-8, 2002 Mar 01.
Article em En | MEDLINE | ID: mdl-11849791
PURPOSE: To evaluate an infrared (IR) marker-based positioning system in patients receiving conformal radiotherapy for prostate cancer. METHODS AND MATERIALS: During 553 treatments, the ability of the IR system to automatically position the isocenter was recorded. Setup errors were measured by means of orthogonal verification films and compared to conventional positioning (using skin drawings and lasers) in 184 treatments. RESULTS: The standard deviation of anteroposterior (AP) and lateral setup errors was significantly reduced with IR marker positioning compared to conventional: 2 vs. 4.8 mm AP (p < 0.01) and 1.6 vs. 3.5 mm laterally (p < 0.01). Longitudinally, the difference was not significant (3.5 vs. 3.0 mm). Systematic errors were on the average smaller AP and laterally for the IR method: 4.1 vs. 7.8 mm AP (p = 0.01) and 3.1 vs. 5.6 mm lateral (p = 0.07). Longitudinally, the IR system resulted in somewhat larger systematic errors: 5.0 vs. 3.4 mm for conventional positioning (p = 0.03). The use of an off-line correction protocol, based on the average deviation measured over the first four fractions, allowed virtual elimination of systematic errors. Inability of the IR system to correctly locate the markers, leading to an executional failure, occurred in 21% of 553 fractions. CONCLUSION: IR marker-assisted patient positioning significantly improves setup accuracy along the AP and lateral axes. Executional failures need to be reduced.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioterapia Conformacional / Raios Infravermelhos Tipo de estudo: Guideline Limite: Humans / Male Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radioterapia Conformacional / Raios Infravermelhos Tipo de estudo: Guideline Limite: Humans / Male Idioma: En Ano de publicação: 2002 Tipo de documento: Article