Your browser doesn't support javascript.
loading
Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and image-guided radiotherapy.
Keller, H; Glass, M; Hinderer, R; Ruchala, K; Jeraj, R; Olivera, G; Mackie, T Rock.
Afiliação
  • Keller H; Department of Medical Physics, University of Wisconsin, Madison 53706-1532, USA. keller@madrad.radiology.wisc.edu
Med Phys ; 29(2): 165-75, 2002 Feb.
Article em En | MEDLINE | ID: mdl-11865988
ABSTRACT
The imaging characteristics of an arc-shaped xenon gas ionization chamber for the purpose of megavoltage CT imaging were investigated. The detector consists of several hundred 320 microm thick gas cavities separated by thin tungsten plates of the same thickness. Dose response, efficiency and resolution parameters were calculated using Monte Carlo simulations. The calculations were compared to measurements taken in a 4 MV photon beam, assuming that the measured signal in the chambers corresponds to the therein absorbed dose. The measured response profiles for narrow and broad incident photon beams could be well reproduced with the Monte Carlo calculations. They show, that the quantum efficiency is 29.2% and the detective quantum efficiency at zero frequency DQE(0) is 20.4% for the detector arc placed in focus with the photon source. For a detector placed out of focus, these numbers even increase. The efficiency of this kind of radiation detector for megavoltage radiation therefore surpasses the reported efficiency of existing detector technologies. The resolution of the detector is quantified with calculated and measured line spread functions. The corresponding modulation transfer functions were determined for different thicknesses of the tungsten plates. They show that the resolution is only slightly dependent on the plate thickness but is predominantly determined by the cell size of the detector. The optimal plate thickness is determined by a tradeoff between quantum efficiency, total signal generation and resolution. Thicker plates are more efficient but the total signal and the resolution decrease with plate thickness. In conclusion, a gas ionization chamber of the described type is a highly efficient megavoltage radiation detector, allowing to obtain CT images with very little dose for a sufficient image quality for anatomy verification. This kind of detector might serve as a model for a future generation of highly efficient radiation detectors.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Fótons / Medicina Nuclear Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Fótons / Medicina Nuclear Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2002 Tipo de documento: Article