Sensitive biomonitoring of monoterpene exposure by gas chromatographic-mass spectrometric measurement of hydroxy terpenes in urine.
Sandner, Frank; Fornara, Jennifer; Dott, Wolfgang; Hollender, Juliane.
Afiliação
  • Sandner F; Institute of Hygiene and Environmental Health, RWTH Aachen, Pauwelsstrasse 30, 52057 Aachen, Germany.
Article em En | MEDLINE | ID: mdl-12401347
ABSTRACT
A gas chromatographic method with mass selective detection was developed which enables the simultaneous determination of the urinary hydroxy terpenes cis-verbenol, alpha-terpineol, myrtenol, carveol, perillyl alcohol and trans-sobrerol. The sample preparation consisted of enzymatic hydrolysis, solid phase extraction (SPE) with RP-C(18) SPE material and clean up with silica gel cartridges. Large volume injection was used and the mass selective detection was done in the single ion modus. Low detection limits in the range of 1.0-4.5 microg/l for the terpene metabolites in urine and mean recoveries of 100% were achieved.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Monoterpenos / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2002 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Monoterpenos / Cromatografia Gasosa-Espectrometria de Massas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2002 Tipo de documento: Article