[Improvement of the determination method of benzene, toluene, ethylbenzene and xylene(BTEX) in water using activated carbon fiber solid-phase microextraction/gas chromatography-mass spectrometry(GC-MS)].
Jia, Jin-ping; Feng, Xue; Fang, Neng-hu; Huang, Jia-liang.
Afiliação
  • Jia JP; School of Environment Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China. jpjia@mail1.sjtu.edu.cn
Se Pu ; 20(1): 63-5, 2002 Jan.
Article em Zh | MEDLINE | ID: mdl-12541623
ABSTRACT
The methods of direct injection, carbon disulfide extraction and activated carbon fiber solid-phase microextraction/GC-MS, usually used in the determination of BTEX in water matrix, are compared and discussed. Experimental data of linearity, precision and limit of detection illustrate that the last one is better than the two other methods. This method was tested by the practical sample experiments and expected to be a simple and sensitive new method for the analysis of BTEX in water.