Sterile mediastinal gas mimicking abscess in aortic aneurysm repair.
Black, C M; Rockoff, S D; Alyono, D.
Afiliação
  • Black CM; Department of Radiology, George Washington University Medical Center, Washington, DC 20037.
Chest ; 102(6): 1911-3, 1992 Dec.
Article em En | MEDLINE | ID: mdl-1446522
ABSTRACT
Six weeks after aortic aneurysm repair, computed tomography (CT) showed mediastinal gas where absorbable gelatin sponge (Gelfoam) was used. A leukocyte scan labeled with indium 111, however, was normal and surgical exploration showed no infection. Sterile gas collections may be seen following absorbable gelatin sponge use many weeks after surgery and 111In-labeled leukocyte scanning may be a useful differential test.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Complicações Pós-Operatórias / Tomografia Computadorizada por Raios X / Abscesso / Gases / Mediastino / Doenças do Mediastino Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 1992 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Complicações Pós-Operatórias / Tomografia Computadorizada por Raios X / Abscesso / Gases / Mediastino / Doenças do Mediastino Tipo de estudo: Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Ano de publicação: 1992 Tipo de documento: Article