Your browser doesn't support javascript.
loading
Diagnosing breast lesions with contrast-enhanced 3-dimensional power Doppler imaging.
Forsberg, Flemming; Goldberg, Barry B; Merritt, Christopher R B; Parker, Laurence; Maitino, Andrea J; Palazzo, Juan J; Merton, Daniel A; Schultz, Susan M; Needleman, Laurence.
Afiliação
  • Forsberg F; Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA. flemming.forsberg@jefferson.edu
J Ultrasound Med ; 23(2): 173-82, 2004 Feb.
Article em En | MEDLINE | ID: mdl-14992354
ABSTRACT

OBJECTIVE:

To compare mammography with contrast-enhanced 2- and 3-dimensional power Doppler imaging for the diagnosis of breast cancer.

METHODS:

Fifty-five patients, who underwent breast biopsies with histopathologic assessment, participated in a study of mammography and contrast-enhanced sonography. Levovist (Berlex Laboratories, Montville, NJ) and Optison (Mallinckrodt, St Louis, MO) were administrated to 22 and 33 patients, respectively. Precontrast and postcontrast 2-dimensional power Doppler data of the lesion were obtained with an HDI 3000 system (Philips Medical Systems, Bothell, WA), and 3-dimensional data were acquired with an LIS 6000A system (Life Imaging Systems Inc, London, Ontario, Canada). Two independent and blinded readers assessed diagnosis. Receiver operating characteristic curves were computed individually and in combination for mammography and 2- and 3-dimensional sonography (before and after contrast). Histopathologic and imaging parameters were compared by Mann-Whitney statistics.

RESULTS:

Mammographic findings were available for 50 patients, biopsy for 54, and 2- and 3-dimensional sonographic images for 53 and 52, respectively. Of the 50 patients who had all 4 measures, 15 (30%) had malignancies. The areas under the receiver operating characteristic curve for the diagnosis of breast cancer were 0.51 for 2-dimensional contrast-enhanced imaging, 0.60 for 3-dimensional power Doppler imaging, and 0.76 for 3-dimensional contrast-enhanced imaging (P < .01). Mammography produced an area of 0.86, which increased when combined with 3-dimensional contrast-enhanced imaging to 0.90 and with all sonographic modalities to 0.96 (P < .001). The histopathologic diagnosis of benign or malignant correlated with the presence or absence of anastomoses and with the degree of vascularity assessed with contrast-enhanced 3-dimensional power Doppler imaging (P = .007 and .02).

CONCLUSIONS:

Contrast-enhanced 3-dimensional power Doppler imaging increases the ability to diagnose breast cancer relative to conventional 2- and 3-dimensional sonographic imaging.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Ultrassonografia Doppler / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Ultrassonografia Doppler / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article