Your browser doesn't support javascript.
loading
Distal protection with a filter device during coronary stenting in patients with stable and unstable angina.
Angelini, Annalisa; Rubartelli, Paolo; Mistrorigo, Flavio; Della Barbera, Mila; Abbadessa, Francesco; Vischi, Massimo; Thiene, Gaetano; Chierchia, Sergio.
Afiliação
  • Angelini A; Department of Pathology, University of Padua Medical School, Via A. Gabelli, 61, 35121 Padua, Italy.
Circulation ; 110(5): 515-21, 2004 Aug 03.
Article em En | MEDLINE | ID: mdl-15277328
ABSTRACT

BACKGROUND:

Filter protection after percutaneous coronary intervention (PCI) is now available to prevent distal embolization. The aims of this study were (1) to evaluate the microembolization phenomenon during procedures of stent implantation in native coronary arteries of patients with stable and unstable angina, (2) to assess the amount and characteristics of the debris captured by the Angioguard, and (3) to investigate the relation between clinical and angiographic variables and pathological data. METHODS AND

RESULTS:

Elective coronary stenting with the use of a protective filter was attempted in 39 consecutive coronary artery lesions with >60% stenosis (mean, 67.6+/-8.79%). Debris was present in 75.6% of the filters. Particle size ranged from 47.16 to 2503.48 microm (mean, 518.83+/-319.61 microm) in the major axis. Particles >300 microm were found in 24 of 28 filters with debris (85.7%), and particles >1000 microm were present in 10 of 28 filters (35.7%). Patients with unstable angina had greater particles (mean maximum longitudinal diameter, 1098.33+/-714.3 microm) than those with stable angina (412.91+/-453 microm; P<0.001). The presence of unstable angina (OR, 65; CI, 1.2 to 3420; P=0.03) and age >67 years (OR, 42; CI, 1 to 1698; P=0.04) were found to be the only independent predictors of embolic particle size.

CONCLUSIONS:

By limiting embolization, protective devices may prevent a number of potentially unfavorable events, thereby improving outcome. Our data support the use of these devices, especially in lesions with higher embolic potential, such as those occurring in older patients and in those with unstable angina.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Filtros de Veia Cava / Estenose Coronária / Embolia / Complicações Intraoperatórias / Angina Pectoris / Angina Instável Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Filtros de Veia Cava / Estenose Coronária / Embolia / Complicações Intraoperatórias / Angina Pectoris / Angina Instável Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article