Misleading high tobramycin plasma concentrations can be caused by skin contamination of fingerprick blood following inhalation of nebulized tobramycin (TOBI): a short report.
Redmann, Stefanie; Wainwright, Claire; Stacey, Sonya; Champion, Anita; Mitchell, Penny; Cheney, Joyce; Charles, Bruce.
Afiliação
  • Redmann S; School of Pharmacy, The University of Queensland, Brisbane, Queensland 4072, Australia. s4045326@student.uq.edu.au
Ther Drug Monit ; 27(2): 205-7, 2005 Apr.
Article em En | MEDLINE | ID: mdl-15795653
ABSTRACT
We observed unexpected high plasma concentrations of tobramycin (48.5 and 28.1 mg/L) in fingerprick blood samples after the nebulization of tobramycin solution for inhalation (tobramycin 300 mg/5 mL, TOBI by 2 young children aged 3 years. To investigate whether dermal contamination could be the source of error, 3 adult volunteers were present during another nebulization by a third child (age 2 years). The volunteers had exposure to tobramycin by handling the nebulizer or the nebule and also by inhalation from holding the child and being in close proximity while TOBI was being administered. Five blood samples by fingerprick and 2 by venipuncture were collected and assayed for tobramycin concentration. On each occasion the site was swabbed with alcohol wipes to mimic standard patient sampling methods. One site was resampled after cleaning of hands with 2% chlorhexidine gluconate and water. Tobramycin concentrations from venipuncture 1-2 hours after nebulization were all <0.2 mg/L except for 1 result of 1.2 mg/L. The tobramycin concentrations from fingerpricks before hand washing varied between 6.8 and 172 mg/L, and after hand washing between 0.3 and 17.6 mg/L. Contamination of fingers with tobramycin is likely to have caused the error in the 2 initial cases and did cause misleadingly elevated levels in the adult volunteers. We caution that therapeutic drug monitoring of nebulized tobramycin should not be done by fingerprick sampling, and care should be taken to avoid contamination of the venipuncture site.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Pele / Tobramicina / Inalação / Flebotomia / Reações Falso-Positivas Limite: Child, preschool / Female / Humans / Male Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Pele / Tobramicina / Inalação / Flebotomia / Reações Falso-Positivas Limite: Child, preschool / Female / Humans / Male Idioma: En Ano de publicação: 2005 Tipo de documento: Article