Simultaneous serodetection of 10 highly prevalent mouse infectious pathogens in a single reaction by multiplex analysis.
Khan, Imran H; Kendall, Lon V; Ziman, Melanie; Wong, Scott; Mendoza, Sara; Fahey, James; Griffey, Stephen M; Barthold, Stephen W; Luciw, Paul A.
Afiliação
  • Khan IH; Center for Comparative Medicine, and Department of Pathology and Laboratory Medicine, University of California at Davis, Davis, California 95616, USA. ihkhan@ucdavis.edu
Clin Diagn Lab Immunol ; 12(4): 513-9, 2005 Apr.
Article em En | MEDLINE | ID: mdl-15817759
ABSTRACT
Under current practices of mouse colony maintenance, sera from mice are analyzed for antibodies against several widespread infectious pathogens by conventional immunoassays, generally enzyme-linked immunosorbent assay (ELISA). To test for multiple agents, these methods consume large volumes of mouse serum and are laborious and time-consuming. More efficient immunoassays, using small amounts of sample, are therefore needed. Accordingly, we have developed a novel multiplex diagnostic system that employs fluorescent microbeads, coated with purified antigens, for simultaneous serodetection of 10 mouse infectious agents. Individually identifiable, fluorescent microbeads were coated with antigens from Sendai virus, mouse hepatitis virus, Theiler's mouse encephalomyelitis virus/GDVII strain, mouse minute virus, mouse cytomegalovirus, respiratory enteric orphan virus (Reo-3 virus), mouse parvovirus, calf rotavirus for epizootic diarrhea virus of infant mice, vaccinia virus for ectromelia virus, and Mycoplasma pulmonis. Standard sera, singly positive for antibodies to individual infectious agents, were generated by inoculation of BALB/cj and C57BL/6j mice. Sera from these experimentally infected mice, as well as sera from naturally infected mice, were analyzed using a mixture of microbeads coated with antigens of the 10 infectious agents listed above. Results demonstrated that the multiplex assay was at least as sensitive and specific as ELISA for serodetection. Importantly, the multiplex assay required only 1 microliter of serum for simultaneous serodetection of the 10 mouse infectious agents in one reaction vessel. Thus, this multiplex microbead assay is a reliable, efficient, and cost-effective diagnostic modality that will impact serosurveillance of mice used in research.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças dos Roedores / Viroses / Anticorpos Antivirais / Antígenos Virais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2005 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças dos Roedores / Viroses / Anticorpos Antivirais / Antígenos Virais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2005 Tipo de documento: Article