Determination of ibuprofen in dog plasma by liquid chromatography and application in pharmacokinetic studies of an ibuprofen prodrug in dogs.
J Pharm Biomed Anal
; 38(4): 714-9, 2005 Jul 15.
Article
em En
| MEDLINE
| ID: mdl-15967300
A liquid chromatography (LC) method for the determination of ibuprofen in dog plasma is described. Chromatographic separation was performed on a Diamonsil C18 column with a C18 guard column using a binary mixture of acetonitrile and 0.02 mol/l phosphate buffer (pH 6.5) (35:65, v/v) delivered at a flow rate of 1.2 ml/min. The linear range for ibuprofen was from 1.0 to 40.0 microg/ml with a limit of quantitation of 1.0 microg/ml. Within-run accuracy and precision ranged from -0.1% to 4.0% and from 1.1% to 5.5% and between-run accuracy and precision ranged from -1.1% to 4.7% and from 1.3% to 7.0%, respectively. The mean extraction recoveries of ibuprofen determined over the concentrations of 1.0, 10.0, and 40.0 microg/ml were (100.5+/-1.8)%, (99.8+/-1.0)%, and (99.2+/-2.3)%. The developed LC method greatly simplified the sample preparation and adopted mild conditions to prevent the possible hydrolysis of the prodrug and was successfully applied to the pharmacokinetic studies of an ibuprofen prodrug in dogs.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Anti-Inflamatórios não Esteroides
/
Ibuprofeno
Limite:
Animals
Idioma:
En
Ano de publicação:
2005
Tipo de documento:
Article